Literature DB >> 21549289

Auscultation in flight: comparison of conventional and electronic stethoscopes.

J P Tourtier1, N Libert, P Clapson, K Tazarourte, M Borne, L Grasser, B Debien, Y Auroy.   

Abstract

OBJECTIVES: The ability to auscultate during air medical transport is compromised by high ambient-noise levels. The aim of this study was to assess the capabilities of a traditional and an electronic stethoscope (which is expected to amplify sounds and reduce ambient noise) to assess heart and breath sounds during medical transport in a Boeing C135.
METHODS: We tested one model of a traditional stethoscope (3MTM Littmann Cardiology IIITM) and one model of an electronic stethoscope (3MTM Littmann Stethoscope Model 3000). We studied heart and lung auscultation during real medical evacuations aboard a medically configured C135. For each device, the quality of auscultation was described using a visual rating scale (ranging from 0 to 100 mm, 0 corresponding to "I hear nothing," 100 to "I hear perfectly"). Comparisons were accomplished using a t-test for paired values.
RESULTS: A total of 36 comparative evaluations were performed. For cardiac auscultation, the value of the visual rating scale was 53 ± 24 and 85 ± 11 mm, respectively, for the traditional and electronic stethoscope (paired t-test: P = .0024). For lung sounds, quality of auscultation was estimated at 27 ± 17 mm for traditional stethoscope and 68 ± 13 for electronic stethoscope (paired t-test: P = .0003). The electronic stethoscope was considered to be better than the standard model for hearing heart and lung sounds.
CONCLUSION: Flight practitioners involved in air medical evacuation in the C135 aircraft are better able to practice auscultation with this electronic stethoscope than with a traditional one.
Copyright © 2011 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21549289     DOI: 10.1016/j.amj.2010.11.009

Source DB:  PubMed          Journal:  Air Med J        ISSN: 1067-991X


  5 in total

1.  In-flight ultrasound identification of pneumothorax.

Authors:  Jacob A Quick; Rindi M Uhlich; Salman Ahmad; Stephen L Barnes; Jeffrey P Coughenour
Journal:  Emerg Radiol       Date:  2015-09-25

2.  Carotid artery ultrasonographic assessment in patients from the Fremantle Diabetes Study Phase II with carotid bruits detected by electronic auscultation.

Authors:  Arthur Knapp; Violetta Cetrullo; Brett A Sillars; Nat Lenzo; Wendy A Davis; Timothy M E Davis
Journal:  Diabetes Technol Ther       Date:  2014-07-02       Impact factor: 6.118

Review 3.  The electronic stethoscope.

Authors:  Shuang Leng; Ru San Tan; Kevin Tshun Chuan Chai; Chao Wang; Dhanjoo Ghista; Liang Zhong
Journal:  Biomed Eng Online       Date:  2015-07-10       Impact factor: 2.819

4.  Design of a Novel Medical Acoustic Sensor Based on MEMS Bionic Fish Ear Structure.

Authors:  Chenzheng Zhou; Junbin Zang; Chenyang Xue; Yuexuan Ma; Xiaoqiang Hua; Rui Gao; Zengxing Zhang; Bo Li; Zhidong Zhang
Journal:  Micromachines (Basel)       Date:  2022-01-22       Impact factor: 2.891

5.  Design and Realization of MEMS Heart Sound Sensor with Concave, Racket-Shaped Cilium.

Authors:  Yuhua Yang; Bo Wang; Jiangong Cui; Guojun Zhang; Renxin Wang; Wendong Zhang; Changde He; Yirui Li; Pengcheng Shi; Shuotong Wang
Journal:  Biosensors (Basel)       Date:  2022-07-18