Literature DB >> 21547697

Instrumented transforaminal lumbar interbody fusion with single cage for the treatment of degenerative lumbar disease.

Jian Zhou1, Bo Wang, Jian Dong, Xilei Li, Xiaogang Zhou, Taolin Fang, Hong Lin.   

Abstract

INTRODUCTION: There are several practical problems encountered in the TLIF procedure with implantation of two titanium cages, such as difficulty in achieving symmetric positioning with two cages, loosening of the first cage following insertion of the second cage and higher direct costs to the patient.
METHOD: From January 2005 to December 2007, a total of 76 consecutive patients treated with instrumented TLIF with single cage and excised local bone were enrolled in the current study. There were 45 males and 31 females aged between 31 and 75 years (mean 50.9 years). Forty-five patients had degenerative disc diseases alone, 23 had associated isthmic or degenerative spondylolisthesis and 8 had recurrent disc herniations. Clinical outcomes were evaluated using the Oswestry Disability Index and a visual analog scale. Intervertebral height and fusion status were assessed on X-ray and two-dimensional computed tomography reconstruction.
RESULTS: All the patients followed up. The mean follow-up period was 21.8 months (range from 12 to 48 months). No nerve injuries occurred during operation. Postoperative ODI and VAS scores in all the patients were more than the preoperative ones with significant differences. All the patients had complete interbody fusion and, at the final follow-up, none had instrumentation failure. Postoperative intervertebral height in all the patients was better than the preoperative ones with statistical significances.
CONCLUSIONS: Instrumented TLIF with single cage is a safe and effective method for the treatment of degenerative lumbar diseases.

Entities:  

Mesh:

Year:  2011        PMID: 21547697     DOI: 10.1007/s00402-011-1292-7

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  7 in total

1.  An RCT study comparing the clinical and radiological outcomes with the use of PLIF or TLIF after instrumented reduction in adult isthmic spondylolisthesis.

Authors:  Er-Zhu Yang; Jian-Guang Xu; Xiao-Kang Liu; Gen-Yang Jin; Wenzhen Xiao; Bing-Fang Zeng; Xiao-Feng Lian
Journal:  Eur Spine J       Date:  2015-12-09       Impact factor: 3.134

2.  Single transverse-orientation cage via MIS-TLIF approach for the treatment of degenerative lumbar disease: a technical note.

Authors:  Shan-Jin Wang; Ying-Chao Han; Fu-Min Pan; Bin Ma; Jun Tan
Journal:  Int J Clin Exp Med       Date:  2015-08-15

Review 3.  [Interbody fusion procedures. Development from a historical perspective].

Authors:  Marcus Rickert; Michael Rauschmann; C Fleege; E Behrbalk; J Harms
Journal:  Orthopade       Date:  2015-02       Impact factor: 1.087

4.  Analysis of single cage position in transforaminal lumbar interbody fusion through digital images.

Authors:  Xin Zhao; Chen Chen; Tangjun Zhou; Jie Mi; Lin Du; Zhanrong Kang; Jianming Huang; Kai Zhang; Xiaojiang Sun; Jie Zhao
Journal:  Int Orthop       Date:  2018-02-11       Impact factor: 3.075

5.  Instrumented transforaminal lumbar interbody fusion in surgical treatment of recurrent disc herniation.

Authors:  Farzad Omidi-Kashani; Ebrahim Ghayem Hasankhani; Hamid Reza Noroozi
Journal:  Med J Islam Repub Iran       Date:  2014-11-01

6.  Analysis of the correlative factors in the selection of interbody fusion cage height in transforaminal lumbar interbody fusion.

Authors:  Hongli Wang; Wenjie Chen; Jianyuan Jiang; Feizhou Lu; Xiaosheng Ma; Xinlei Xia
Journal:  BMC Musculoskelet Disord       Date:  2016-01-12       Impact factor: 2.362

7.  Transforaminal lumbar interbody fusion using a modified distractor handle: a midterm clinicoradiological follow-up study.

Authors:  Abuduaini Rewuti; Zixian Chen; Zhenzhou Feng; Yuanwu Cao; Xiaoxing Jiang; Chun Jiang
Journal:  Biomed Res Int       Date:  2013-09-09       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.