In vitro study of the optimum volume ratio of activator to adhesive in gelatin-resorcin-formalin glue.

Susumu Isoda1, Tamizo Kimura, Yuji Mashiko, Shingo Nakamura, Tadaaki Maehara.   

Abstract

OBJECTIVE: Excessive use of activator (formaldehyde + glutaraldehyde) may cause late complications after use of gelatin-resorcin-formalin (GRF) glue during surgery. The goal of the study was to define the appropriate ratio of activator to adhesive and to establish an approach for accurate control of this ratio.
METHODS: The relation between adhesive force and the activator/adhesive ratio was studied by attaching two sheets of equine pericardium using GRF glue, with ratios from 1: 50 to 1: 2. The amount of activator was measured per drip from the needle in the GRF glue kit and other needles (27, 25, 23, 22, and 21 gauge).
RESULTS: The adhesive force was about 400 gram-weight (gw) for activator/adhesive ratios from 1: 50 to 1: 20. This force showed a significant increase to 1317 ± 462 gw for a ratio of 1: 10 compared to the force at a ratio 1: 20 (P = 0.0069) but did not increase significantly for ratios above 1: 10. The activator volume was 12.5 μl in one drip from the needle in the GRF glue kit and 4.3 μl in one drip from the 27-gauge needle. Therefore, the 27-gauge needle is suitable for measuring the activator volume.
CONCLUSION: In vitro, an activator at a ratio of one-tenth the volume of the adhesive provides approximately maximum force; any more activator is residual and potentially harmful. Measurement of the activator volume using a 27-gauge needle and the adhesive volume using a syringe is recommended to control the ratio accurately.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21547625     DOI: 10.1007/s11748-009-0552-8

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  4 in total

1.  Late complications of gelatin-resorcin-formalin glue in the repair of acute type A aortic dissection.

Authors:  Hiroki Hata; Hiroshi Takano; Goro Matsumiya; Norihide Fukushima; Naomasa Kawaguchi; Yoshiki Sawa
Journal:  Ann Thorac Surg       Date:  2007-05       Impact factor: 4.330

2.  Recommendation for appropriate use of GRF glue in the operation for acute aortic dissection.

Authors:  Takashi Kunihara; Norihiko Shiiya; Kenji Matsuzaki; Toshifumi Murashita; Yoshiro Matsui
Journal:  Ann Thorac Cardiovasc Surg       Date:  2008-04       Impact factor: 1.520

3.  Type A acute aortic dissection: immediate and mid-term results of emergency aortic replacement with the aid of gelatin resorcin formalin glue.

Authors:  Mitsumasa Hata; Motomi Shiono; Akira Sezai; Mitsuru Iida; Nanao Negishi; Yukiyasu Sezai
Journal:  Ann Thorac Surg       Date:  2004-09       Impact factor: 4.330

4.  Sandwich technique via right ventricle incision to repair postinfarction ventricular septal defect.

Authors:  S Isoda; K Imoto; K Uchida; N Hashiyama; H Yanagi; H Tamagawa; Y Takanashi
Journal:  J Card Surg       Date:  2004 Mar-Apr       Impact factor: 1.620

  4 in total
  3 in total

1.  Recent status of gelatin-resorcin-formalin glue for acute type A aortic dissection.

Authors:  Kiyotaka Imoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-05-06

2.  Pitfalls for the "Sandwich technique" via a right ventricular incision to repair post-infarction ventricular septal defects.

Authors:  Susumu Isoda; Kiyotaka Imoto; Keiji Uchida; Norihisa Karube; Keiichiro Kasama; Ichiya Yamazaki; Shinichi Suzuki; Yoshimi Yano; Yusuke Matsuki; Munetaka Masuda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-10-15

3.  Efficacy of Glutaraldehyde-Treated Leaflets for Mitral Valve Repair to Treat Active Infective Endocarditis: A Case Report.

Authors:  Susumu Isoda; Ichiya Yamazaki; Yusuke Matsuki; Hiroto Tomita; Yoshimi Yano; Toshikazu Gondo; Munetaka Masuda
Journal:  Ann Thorac Cardiovasc Surg       Date:  2018-03-16       Impact factor: 1.520