Literature DB >> 21545346

Incurred sample accuracy assessment: design of experiments based on standard addition.

Theo de Boer1, Jaap Wieling.   

Abstract

It is commonly acknowledged that random and systematic analytical errors contribute to poor data quality, and moreover, to imprecise and inaccurate pharmacokinetic parameters. To investigate the random errors in GLP bioanalysis, common ground has been found in today's bioanalysis to assess the reproducibility of the method by reanalyzing part of the incurred samples. The undesired systematic errors in bioanalysis affecting the trueness of the method and leading to inaccurate data remain relatively unattended so far. In order to obtain both precise and accurate data it is suggested in this paper to apply standard addition experiments to calculate the relative systematic errors as an estimate for the incurred sample accuracy. This approach, which can be seen as an important extension to current guidelines in GLP bioanalysis, is illustrated by assessing the accuracy of the bioanalytical results for a bioequivalence study for alendronate.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21545346     DOI: 10.4155/bio.11.36

Source DB:  PubMed          Journal:  Bioanalysis        ISSN: 1757-6180            Impact factor:   2.681


  7 in total

1.  Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC-MS/MS.

Authors:  Shiva Kumar Gudlawar; Nageswara Rao Pilli; Sridhar Siddiraju; Jaya Dwivedi
Journal:  J Pharm Anal       Date:  2013-12-27

2.  A rapid and sensitive liquid chromatography-tandem mass spectrometric assay for duloxetine in human plasma: Its pharmacokinetic application.

Authors:  Ramakrishna Gajula; Rambabu Maddela; Vasu Babu Ravi; Jaswanth Kumar Inamadugu; Nageswara Rao Pilli
Journal:  J Pharm Anal       Date:  2012-10-07

3.  Simultaneous determination of atorvastatin, metformin and glimepiride in human plasma by LC-MS/MS and its application to a human pharmacokinetic study.

Authors:  Srinivasa Rao Polagani; Nageswara Rao Pilli; Ramakrishna Gajula; Venkateswarlu Gandu
Journal:  J Pharm Anal       Date:  2012-10-03

4.  Simultaneous Determination of Atorvastatin and Aspirin in Human Plasma by LC-MS/MS: Its Pharmacokinetic Application.

Authors:  Ramakrishna Gajula; Nageswara Rao Pilli; Vasu Babu Ravi; Rambabu Maddela; Jaswanth Kumar Inamadugu; Srinivasa Rao Polagani; Sobha Busa
Journal:  Sci Pharm       Date:  2012-08-06

5.  Simultaneous determination of rosuvastatin and amlodipine in human plasma using tandem mass spectrometry: Application to disposition kinetics.

Authors:  Anjaneyulu Narapusetti; Syama Sundar Bethanabhatla; Anbazhagan Sockalingam; Nagakishore Repaka; Veldandi Saritha
Journal:  J Adv Res       Date:  2014-09-06       Impact factor: 10.479

6.  Validated UPLC-MS/MS method for the determination of tadalafil in human plasma and its application to a pharmacokinetic study.

Authors:  Kwang-Youl Kim; Moonsuk Nam; Hyun-Jung Kwon; Kwang-Hyeon Kim; Seung-Hyun Kang; Sang-Il Kim; Cheol-Woo Kim; Sang-Heon Cho
Journal:  Transl Clin Pharmacol       Date:  2017-03-15

7.  Development and Validation of an LC-MS/MS Assay to Quantitate 2',4',6'-Trihydroxyacetophenone in Rat and Dog Plasma and its Application to a Pharmacokinetic Study.

Authors:  Hee Jo Yoo; Se-Jung Hwang; Jeong-Hun Lee; Wang-Seob Shim; Yun-Woong Choi; Sang Min Cho; Eun Kyoung Chung; Jun-Bom Park; Kyung-Tae Lee
Journal:  Molecules       Date:  2020-09-23       Impact factor: 4.411