OBJECTIVE: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous™ endothelial progenitor cell capturing R stent™ placement in patients from the e-HEALING registry.
BACKGROUND: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended.
METHODS: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression.
RESULTS: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.65-1.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.55-1.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable.
CONCLUSIONS: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21542121     DOI: 10.1002/ccd.23156

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  1 in total

1.  Anti-platelet and tissue engineering approaches to biomaterial blood compatibilization: how well have these been translated into the clinic?

Authors:  Scott Alexander Irvine; Xia Yun; Subbu Venkatraman
Journal:  Drug Deliv Transl Res       Date:  2012-10       Impact factor: 4.617

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.