Literature DB >> 21540973

Precision angle sensor using an optical lever inside a Sagnac interferometer.

J M Hogan1, J Hammer, S-W Chiow, S Dickerson, D M S Johnson, T Kovachy, A Sugarbaker, M A Kasevich.   

Abstract

We built an ultra-low-noise angle sensor by combining a folded optical lever and a Sagnac interferometer. The instrument has a measured noise floor of 1.3 prad/√Hz at 2.4 kHz. We achieve this record angle sensitivity using a proof-of-concept apparatus with a conservative N=11 bounces in the optical lever. This technique could be extended to reach subpicoradian/√Hz sensitivities with an optimized design.

Year:  2011        PMID: 21540973     DOI: 10.1364/OL.36.001698

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  2 in total

1.  Using a Hexagonal Mirror for Varying Light Intensity in the Measurement of Small-Angle Variation.

Authors:  Meng-Chang Hsieh; Jiun-You Lin; Chia-Ou Chang
Journal:  Sensors (Basel)       Date:  2016-08-16       Impact factor: 3.576

2.  Investigating the Effects of the Interaction Intensity in a Weak Measurement.

Authors:  Fabrizio Piacentini; Alessio Avella; Marco Gramegna; Rudi Lussana; Federica Villa; Alberto Tosi; Giorgio Brida; Ivo Pietro Degiovanni; Marco Genovese
Journal:  Sci Rep       Date:  2018-05-03       Impact factor: 4.379

  2 in total