Literature DB >> 21540493

Uncertainty in hyperthermia treatment planning: the need for robust system design.

M de Greef1, H P Kok, D Correia, P-P Borsboom, A Bel, J Crezee.   

Abstract

Hyperthermia treatment planning (HTP) is an important tool to improve the quality of hyperthermia treatment. It is a practical way of designing new hyperthermia systems and can be used to optimize the phase and amplitude settings to achieve optimal heating. One of the main challenges to be dealt with however is the uncertainty in the modeling parameters. The role of dielectric and combined dielectric and perfusion uncertainty on optimization was investigated by means of HTP for six different systems: the 70 MHz AMC-4 (AMC: Academic Medical Center) and AMC-8 system, a 130 MHz version of the AMC-8 system, a three-ring AMC-12 system operating at 130 MHz, the BSD SigmaEye applicator and a dipole applicator with three rings each containing six dipole pairs operated at 150 MHz. For five patients with cervix uteri carcinoma, a patient model was created based on a hyperthermia planning CT. Variation of tissue parameters resulted in 16 dielectric models for every patient. In addition, four thermal models were created to study the combined effect of perfusion and dielectric uncertainty. The impact of dielectric uncertainty on optimization is found to be clearly dependent on the number of channels and increased from 0.5 °C for four channels to 1.5 °C for the 18-channel system. As a result, the potential gain relative to the AMC-4 system for the 70 MHz AMC-8 system was found to be largely compromised, while for the remaining systems a robust improvement in T(90) was observed. The dipole applicator showed the best target heating for two out of five patients, while for three others heating efficacy was comparable to the 130 MHz AMC-12 system or the 130 MHz AMC-8 system (one patient). Considering the increase in complexity when the number of channels is increased from 12 to 18, the AMC-12 system is considered as a good compromise between heating efficacy and robustness while still being a manageable heating system in clinical practice.

Entities:  

Mesh:

Year:  2011        PMID: 21540493     DOI: 10.1088/0031-9155/56/11/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Benefit of replacing the Sigma-60 by the Sigma-Eye applicator. A Monte Carlo-based uncertainty analysis.

Authors:  R A M Canters; M M Paulides; M Franckena; J W Mens; G C van Rhoon
Journal:  Strahlenther Onkol       Date:  2012-11-18       Impact factor: 3.621

Review 2.  Heating technology for malignant tumors: a review.

Authors:  H Petra Kok; Erik N K Cressman; Wim Ceelen; Christopher L Brace; Robert Ivkov; Holger Grüll; Gail Ter Haar; Peter Wust; Johannes Crezee
Journal:  Int J Hyperthermia       Date:  2020       Impact factor: 3.914

Review 3.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

4.  Thermal magnetic resonance: physics considerations and electromagnetic field simulations up to 23.5 Tesla (1GHz).

Authors:  Lukas Winter; Celal Oezerdem; Werner Hoffmann; Tessa van de Lindt; Joao Periquito; Yiyi Ji; Pirus Ghadjar; Volker Budach; Peter Wust; Thoralf Niendorf
Journal:  Radiat Oncol       Date:  2015-09-22       Impact factor: 3.481

5.  B1-based SAR reconstruction using contrast source inversion-electric properties tomography (CSI-EPT).

Authors:  Edmond Balidemaj; Cornelis A T van den Berg; Astrid L H M W van Lier; Aart J Nederveen; Lukas J A Stalpers; Hans Crezee; Rob F Remis
Journal:  Med Biol Eng Comput       Date:  2016-04-23       Impact factor: 2.602

Review 6.  Integrating Loco-Regional Hyperthermia Into the Current Oncology Practice: SWOT and TOWS Analyses.

Authors:  Niloy R Datta; H Petra Kok; Hans Crezee; Udo S Gaipl; Stephan Bodis
Journal:  Front Oncol       Date:  2020-06-12       Impact factor: 6.244

7.  Accuracy and precision of electrical permittivity mapping at 3T: the impact of three B 1 + mapping techniques.

Authors:  Soraya Gavazzi; Cornelis A T van den Berg; Alessandro Sbrizzi; H Petra Kok; Lukas J A Stalpers; Jan J W Lagendijk; Hans Crezee; Astrid L H M W van Lier
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

8.  Fast Adaptive Temperature-Based Re-Optimization Strategies for On-Line Hot Spot Suppression during Locoregional Hyperthermia.

Authors:  H Petra Kok; Johannes Crezee
Journal:  Cancers (Basel)       Date:  2021-12-28       Impact factor: 6.639

Review 9.  Current state of the art of regional hyperthermia treatment planning: a review.

Authors:  H P Kok; P Wust; P R Stauffer; F Bardati; G C van Rhoon; J Crezee
Journal:  Radiat Oncol       Date:  2015-09-17       Impact factor: 3.481

  9 in total