Diathermocoagulation in cutting mode and large flap dissection.

Pascal Rousseau1, Huguier Vincent, Benoit Potier, Daniel Arnaud, Vincent Darsonval.   

Abstract

BACKGROUND: The aim of this study was to determine the overall complication rate associated with the use of diathermocoagulation in cutting mode for flap dissection.
METHODS: Because of the high rate of complications generally associated with abdominoplasty, a large flap, abdominoplasty, or abdominal dermolipectomy model was chosen. A retrospective review was conducted regarding 647 abdominoplasty procedures, 320 of which were performed with the monopolar diathermocoagulation in the cutting mode and 327 of which were performed with a steel scalpel. The two groups were similar regarding morphologic characteristics, prescriptions, and procedures. In both cases, hemostasis was performed with punctual monopolar coagulation current. Analysis was performed regarding the frequency of major general complications (e.g., deep vein thrombosis and pulmonary embolism), major surgical complications (e.g., acute hemorrhage), and "minor" complications (e.g., postoperative secondary collections or delayed wound healing).
RESULTS: In the electrosurgery group, the incidence of noninfectious collections was significantly higher, as was the production of the drains. No difference was seen in terms of reintervention for acute hematoma, postoperative infectious collections, blood loss, hospital stay, or thromboembolic complications. Operations took significantly longer with the steel scalpel. The follow-up was significantly longer in the diathermocoagulation group.
CONCLUSIONS: Monopolar diathermocoagulation has already proven its place in the general work of every surgeon. Moreover, this technique remains superior in terms of the rapidity with which surgery can be performed when dissecting large areas. Nevertheless, the higher rate of surgical complications leads to a longer follow-up period that, in part, runs counter to this advantage.

Entities:  

Mesh:

Year:  2011        PMID: 21532437     DOI: 10.1097/PRS.0b013e31820cf46e

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  11 in total

Review 1.  Abdominoplasty with Scarpa Fascia Preservation: A Systematic Review and Meta-analysis.

Authors:  Wilson A Wijaya; Yu Liu; YinHai He; Yong Qing; Zhengyong Li
Journal:  Aesthetic Plast Surg       Date:  2022-03-17       Impact factor: 2.326

2.  LigaSure Impact™ reduces complications after abdominoplasty in weight loss patients.

Authors:  Sonia Radunz; Haider Salem; Philipp Houben; Andreas Pascher; Martin Büsing; Markus Utech
Journal:  Langenbecks Arch Surg       Date:  2021-08-31       Impact factor: 2.895

3.  The use of plasmakinetic cautery compared to conventional electrocautery for dissection of abdominal free flap for breast reconstruction: single-centre, randomized controlled study.

Authors:  Whitney T H Chow; Georgette Oni; Venkat V Ramakrishnan; Mat Griffiths
Journal:  Gland Surg       Date:  2019-06

4.  Final 24-hour Drain Output and Postoperative Day Are Poor Indicators for Appropriate Drain Removal.

Authors:  Charleston Chua; Corey M Bascone; Clifford Pereira; Josephine Hai; Jeannie Park; Kelsey Hideshima; Satninderdeep Bhatti; Shadi Nemanpour; Bella Leon; Gloria Han
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-04-14

5.  Dissection Technique for Abdominoplasty: A Prospective Study on Scalpel versus Diathermocoagulation (Coagulation Mode).

Authors:  Rita Valença-Filipe; Apolino Martins; Álvaro Silva; Luis O Vásconez; José Amarante; António Costa-Ferreira
Journal:  Plast Reconstr Surg Glob Open       Date:  2015-02-06

6.  Quilting Sutures, Scarpa Fascia Preservation, and Meta-Analyses of Seroma Rates after Abdominoplasty.

Authors:  Eric Swanson
Journal:  Plast Reconstr Surg Glob Open       Date:  2017-07-05

7.  Aesthetic and Functional Abdominoplasty: Anatomical and Clinical Classification based on a 12-year Retrospective Study.

Authors:  Marco Klinger; Francesco Klinger; Silvia Giannasi; Valeria Bandi; Valeriano Vinci; Barbara Catania; Andrea Lisa; Alessandra Veronesi; Andrea Battistini; Micol Giaccone; Fabio Caviggioli; Luca Maione
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-12-20

8.  Comparing Seroma Formation at the Deep Inferior Epigastric Perforator, Transverse Musculocutaneous Gracilis, and Superior Gluteal Artery Perforator Flap Donor Sites after Microsurgical Breast Reconstruction.

Authors:  Alisha Merchant; Nicole E Speck; Michal Michalak; Dirk J Schaefer; Jian Farhadi
Journal:  Arch Plast Surg       Date:  2022-07-30

9.  Use of Tumescence for Outpatient Abdominoplasty and Other Concurrent Body Contouring Procedures: A Review of 65 Consecutive Patients.

Authors:  Nathaniel L Holzman; Mansher Singh; Stephanie A Caterson; Elof Eriksson; Bohdan Pomahac
Journal:  Eplasty       Date:  2015-09-01

10.  Electrocautery Devices With Feedback Mode and Teflon-Coated Blades Create Less Surgical Smoke for a Quality Improvement in the Operating Theater.

Authors:  Tobias Kisch; Eirini Liodaki; Robert Kraemer; Peter Mailaender; Matthias Brandenburger; Veronika Hellwig; Felix H Stang
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.817