Literature DB >> 21532246

[Quantitative evaluation of calcium (content) in the coronary artery using hybrid iterative reconstruction (iDose) algorithm on low-dose 64-detector CT: comparison of iDose and filtered back projection].

Hiroo Murazaki1, Yoshinori Funama, Masahiro Hatemura, Chikako Fujioka, Seiji Tomiguchi.   

Abstract

To evaluate the usefulness of hybrid iterative reconstruction (iDose) for quantification of calcium content in the coronary artery on 64-detector computed tomography (CT), an anthropomorphic cardiac CT phantom containing cylinders with known calcium content was scanned at tube current-time products of 15, 20, 25, and 50 mAs using 64-detector CT. The images obtained at 15, 20, 25, and 50 mAs were reconstructed using filtered back projection (FBP), and those at 15, 20, and 25 mAs were also reconstructed using iDose. Then the volume and mass of the calcium content in the cylinders were calculated and compared with the true values. The Agatston score was also evaluated. The Agatston score and mass of calcium obtained at 50 mAs using FBP were 656.92 and 159.91 mg, respectively. In contrast, those obtained at 25 mAs using iDose were 641.91 and 159.05 mg, respectively. No significant differences were found in the calcium measurements obtained using FBP and iDose. In addition, the Agatston score and mass of calcium obtained at 15 mAs and 20 mAs using iDose were not significantly different from those obtained at 25 mAs with iDose. By using iDose, accurate quantification of calcium in the coronary artery can be achieved at 15 mAs using 64-detector CT. The radiation dose can be significantly reduced in coronary artery calcium scoring without impairing the detection and quantification of coronary calcification.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21532246     DOI: 10.6009/jjrt.67.360

Source DB:  PubMed          Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi        ISSN: 0369-4305


  7 in total

1.  Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT.

Authors:  Antoine Hutt; Alain Duhamel; Valérie Deken; Jean-Baptiste Faivre; Francesco Molinari; Jacques Remy; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2015-09-04       Impact factor: 5.315

2.  Feasibility of low-radiation-dose CT for abdominal examinations with hybrid iterative reconstruction algorithm: low-contrast phantom study.

Authors:  Masatoshi Kondo; Masamitsu Hatakenaka; Ko Higuchi; Taisuke Fujioka; Takashi Shirasaka; Yasuhiko Nakamura; Katsumasa Nakamura; Takashi Yoshiura; Hiroshi Honda
Journal:  Radiol Phys Technol       Date:  2013-01-09

3.  Influence of iterative image reconstruction on CT-based calcium score measurements.

Authors:  Jochen A C van Osch; Mohamed Mouden; Jorn A van Dalen; Jorik R Timmer; Stoffer Reiffers; Siert Knollema; Marcel J W Greuter; Jan Paul Ottervanger; Piet L Jager
Journal:  Int J Cardiovasc Imaging       Date:  2014-03-28       Impact factor: 2.357

4.  Influence of iterative reconstruction on coronary calcium scores at multiple heart rates: a multivendor phantom study on state-of-the-art CT systems.

Authors:  N R van der Werf; M J Willemink; T P Willems; M J W Greuter; T Leiner
Journal:  Int J Cardiovasc Imaging       Date:  2017-12-28       Impact factor: 2.357

5.  Dose reduction for coronary calcium scoring with hybrid and model-based iterative reconstruction: an ex vivo study.

Authors:  Annemarie M den Harder; Martin J Willemink; Ronald L A W Bleys; Pim A de Jong; Ricardo P J Budde; Arnold M R Schilham; Tim Leiner
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-03       Impact factor: 2.357

6.  Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT.

Authors:  Andrew D Choi; Eric S Leifer; Jeannie Yu; Sujata M Shanbhag; Kathie Bronson; Andrew E Arai; Marcus Y Chen
Journal:  J Cardiovasc Comput Tomogr       Date:  2016-07-27

7.  Computed Tomography Imaging under Artificial Intelligence Reconstruction Algorithm Used in Recovery of Sports Injury of the Knee Anterior Cruciate Ligament.

Authors:  Heng Zhang; Haiming Zheng; Ren Deng; Kaiwen Luo; Shukai Duan
Journal:  Contrast Media Mol Imaging       Date:  2022-05-28       Impact factor: 3.009

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.