Literature DB >> 21531377

Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.

Nikolaos G Baikoussis1, Efstratios Apostolakis, Nikolaos A Papakonstantinou, Ioannis Sarantitis, Dimitrios Dougenis.   

Abstract

Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutures, mediastinal vascular clips, and epicardial pacing wires are not contraindications for MRI, in contrast to pacemakers and implantable cardioverter-defibrillators. Appropriate patient selection and precautions ensure MRI safety. However it is commonly accepted that although hundreds of patients with pacemakers or implantable cardioverter-defibrillators have undergone safe MRI scanning, it is not a safe procedure. Currently, heating of the pacemaker lead is the major problem undermining MRI safety. According to the US Food and Drug Administration (FDA), there are currently neither "MRI-safe" nor "MRI-compatible" pacemakers and implantable cardioverter-defibrillators. In this article we review the international literature in regard to safety during MRI of patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.
Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21531377     DOI: 10.1016/j.athoracsur.2011.02.068

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  13 in total

Review 1.  Clinical use of cardiac PET/MRI: current state-of-the-art and potential future applications.

Authors:  Patrick Krumm; Stefanie Mangold; Sergios Gatidis; Konstantin Nikolaou; Felix Nensa; Fabian Bamberg; Christian la Fougère
Journal:  Jpn J Radiol       Date:  2018-03-10       Impact factor: 2.374

2.  Follow-up and management of valvular heart disease patients with prosthetic valve: a clinical practice guideline for Indian scenario.

Authors:  Devendra Saksena; Yugal K Mishra; S Muralidharan; Vivek Kanhere; Pankaj Srivastava; C P Srivastava
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-01-28

Review 3.  Role of CT in the Pre- and Postoperative Assessment of Conotruncal Anomalies.

Authors:  Parveen Kumar; Mona Bhatia
Journal:  Radiol Cardiothorac Imaging       Date:  2022-06-30

Review 4.  Role of Cardiac MRI Imaging of Focal and Diffuse Inflammation and Fibrosis in Cardiomyopathy Patients Who Have Pacemakers/ICD Devices.

Authors:  Ananna Zaman; Samantha Zhao; Jordana Kron; Antonio Abbate; Anna Tomdio; W Gregory Hundley; Jennifer H Jordan
Journal:  Curr Cardiol Rep       Date:  2022-08-19       Impact factor: 3.955

5.  Transrectal ultrasound and magnetic resonance imaging measurement of extramural tumor spread in rectal cancer.

Authors:  Søren R Rafaelsen; Chris Vagn-Hansen; Torben Sørensen; John Pløen; Anders Jakobsen
Journal:  World J Gastroenterol       Date:  2012-09-28       Impact factor: 5.742

6.  Elastography and diffusion-weighted MRI in patients with rectal cancer.

Authors:  Søren R Rafaelsen; Chris Vagn-Hansen; Torben Sørensen; Jan Lindebjerg; John Pløen; Anders Jakobsen
Journal:  Br J Radiol       Date:  2015-09-24       Impact factor: 3.039

Review 7.  [Modern imaging of kidney tumors].

Authors:  D-A Clevert; A Sterzik; M Braunagel; M Notohamiprodjo; A Graser
Journal:  Urologe A       Date:  2013-04       Impact factor: 0.639

8.  Aortic dissection assessment by 4D phase-contrast MRI with hemodynamic parameters: the impact of stent type.

Authors:  Chien-Wei Chen; Yuan-Hsi Tseng; Chien-Chao Lin; Chih-Chen Kao; Min Yi Wong; Hua Ting; Yao-Kuang Huang
Journal:  Quant Imaging Med Surg       Date:  2021-02

Review 9.  Modulation techniques for biomedical implanted devices and their challenges.

Authors:  Mahammad A Hannan; Saad M Abbas; Salina A Samad; Aini Hussain
Journal:  Sensors (Basel)       Date:  2011-12-28       Impact factor: 3.576

10.  Issues with radiofrequency heating in MRI.

Authors:  Jihong Wang
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.