Literature DB >> 21530776

Application of renewable silver amalgam annular band electrode to voltammetric determination of vitamins C, B1 and B2.

Bogusław Baś1, Małgorzata Jakubowska, Łukasz Górski.   

Abstract

In this work, the design and results of applying silver liquid amalgam film-modified silver solid amalgam annular band electrode (AgLAF-AgSAE), refreshed before each measurement, to voltammetric determination of vitamins C (VC), B(1) (VB1) and B(2) (VB2) are presented. The method is based on adsorptive accumulation of analytes at the AgLAF-AgSAE in a phosphate buffer (VB1), phosphate buffer with Triton X-100 (VB2) and an alkaline borate buffer with Triton X-100 (VC). The analytical parameters and procedure of electrode activation were optimized. The calibration graphs obtained for vitamins C, B(1) and B(2) are linear, respectively, for concentration range 0.05-12, 0.01-0.1 and 0.05-3 mg L(-1). The detection limits were calculated and equaled 0.02, 0.003 and 0.009 mg L(-1), while repeatability of the peak current was 2%, 1% and 3%, respectively. These results are comparable with results obtained for polarographic determination of the same vitamins using mercury electrodes. Finally, the AgLAF-AgSAE was applied to the determination of vitamins in pharmaceutical samples and fruit juices with satisfactory results.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21530776     DOI: 10.1016/j.talanta.2011.03.006

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  A Review of the Extraction and Determination Methods of Thirteen Essential Vitamins to the Human Body: An Update from 2010.

Authors:  Yuan Zhang; Wei-E Zhou; Jia-Qing Yan; Min Liu; Yu Zhou; Xin Shen; Ying-Lin Ma; Xue-Song Feng; Jun Yang; Guo-Hui Li
Journal:  Molecules       Date:  2018-06-19       Impact factor: 4.411

2.  Rapid Detection of Ascorbic Acid Based on a Dual-Electrode Sensor System Using a Powder Microelectrode Embedded with Carboxyl Multi-Walled Carbon Nanotubes.

Authors:  Bao-Shan He; Jun-Xia Zhang
Journal:  Sensors (Basel)       Date:  2017-07-02       Impact factor: 3.576

3.  Highly Sensitive Determination of Tenofovir in Pharmaceutical Formulations and Patients Urine-Comparative Electroanalytical Studies Using Different Sensing Methods.

Authors:  Natalia Festinger; Kaja Spilarewicz-Stanek; Kamila Borowczyk; Dariusz Guziejewski; Sylwia Smarzewska
Journal:  Molecules       Date:  2022-03-19       Impact factor: 4.411

  3 in total