Literature DB >> 21529811

Effect of acetabular component anteversion on dislocation mechanisms in total hip arthroplasty.

Masaru Higa1, Hiromasa Tanino, Masayoshi Abo, Satoshi Kakunai, Scott A Banks.   

Abstract

Quantifying soft-tissue tension around the hip joint during total hip arthroplasty remains difficult. In this study, a three-dimensional computer-aided design model was developed to clarify how component position in total hip arthroplasty contributes to the primary cause of posterior dislocation in cases of flexion, adduction and internal rotation. To better understand the influences of anteversion angle of the acetabular component, its effects on the primary causes of dislocations and the range of motion were investigated. Three different primary dislocation mechanisms were noted: impingement of the prosthetic femoral neck on the cup liner; impingement of the osseous femur on the osseous pelvis; and spontaneous dislocation caused by soft-tissue traction without impingement. Spontaneous dislocation could be detected by calculating hip forces at any thigh position using the computer-aided design model developed. In computer analysis, a transition from prosthetic impingement rate to osseous impingement rate occurred with increasing anteversion angle of the acetabular component. Spontaneous dislocation was detected at angles > 10° of anteversion of the acetabular component when flexion occurred with extreme adduction and internal rotation. This study demonstrated the possibility of spontaneous dislocation that results not from prosthetic or bony impingement but from muscle traction with increased range of motion.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21529811     DOI: 10.1016/j.jbiomech.2011.04.002

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Authors:  Wei-Min Chi; Chien-Chung Lin; Ying-Jui Ho; Hsiao-Che Lin; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2017-07-01       Impact factor: 2.602

2.  A new method for intraoperative assessment of leg length, sizing and placement of the components in total hip replacement.

Authors:  Ioannis P Stathopoulos; Nicolaos Andrianopoulos; Dimitrios Paschaloglou; Kalliopi Lampropoulou-Adamidou; Maria Spetsaki; Ioannis K Tsarouchas
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-02

3.  Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up.

Authors:  Josef Baghdadi; Shareef Alkhateeb; Alexander Roth; Marcus Jäger
Journal:  Arch Orthop Trauma Surg       Date:  2022-04-10       Impact factor: 3.067

4.  Accuracy and Reliability of Software Navigation for Acetabular Component Placement in THA: An In Vitro Validation Study.

Authors:  Alex W Brady; Jakub Tatka; Lorenzo Fagotti; Bryson R Kemler; Bradley W Fossum
Journal:  Medicina (Kaunas)       Date:  2022-05-14       Impact factor: 2.948

5.  The impact of hip implant alignment on muscle and joint loading during dynamic activities.

Authors:  Casey A Myers; Peter J Laz; Kevin B Shelburne; Dana L Judd; Daniel N Huff; Joshua D Winters; Jennifer E Stevens-Lapsley; Paul J Rullkoetter
Journal:  Clin Biomech (Bristol, Avon)       Date:  2018-02-14       Impact factor: 2.063

6.  Fixation method does not affect restoration of rotation center in hip replacements: a single-site retrospective study.

Authors:  Alexander Wegner; Max Daniel Kauther; Stefan Landgraeber; Marius von Knoch
Journal:  J Orthop Surg Res       Date:  2012-06-11       Impact factor: 2.359

7.  A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions.

Authors:  Sven Herrmann; Daniel Kluess; Michael Kaehler; Robert Grawe; Roman Rachholz; Robert Souffrant; János Zierath; Rainer Bader; Christoph Woernle
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

Review 8.  Acetabular cup position and risk of dislocation in primary total hip arthroplasty.

Authors:  Kurt G Seagrave; Anders Troelsen; Henrik Malchau; Henrik Husted; Kirill Gromov
Journal:  Acta Orthop       Date:  2016-11-23       Impact factor: 3.717

  8 in total