Literature DB >> 21529131

Noninvasive assessment of intracranial pressure with venous ophthalmodynamometry. Clinical article.

Raimund Firsching1, Claudia Müller, Steffen-Ulrich Pauli, Benjamin Voellger, Friedrich-Wilhelm Röhl, Wolfgang Behrens-Baumann.   

Abstract

OBJECT: Venous ophthalmodynamometry is a technique used to register the pressure within the central retinal vein. Because the outflow of the central retinal vein is exposed to the intracranial pressure (ICP), the pressure of the central retinal vein may be correlated with the ICP. In the absence of adequate statistical evidence, the authors compared the pressure of the central retinal vein with results of simultaneous invasive monitoring of ICP in neurosurgical patients.
METHODS: The pressure within the central retinal vein was recorded in 102 patients, in whom invasive continuous monitoring of ICP had become necessary for various reasons, mostly because of suspected hydrocephalus and intracranial hemorrhage.
RESULTS: A highly significant correlation of the pressure in the central retinal vein and the intracranial cavity was confirmed statistically. An increased pressure of the central retinal vein indicated an elevated ICP, with a probability of 84.2%, whereas a normal pressure of the central retinal vein indicated a normal ICP in 92.8% of patients. Conclusions Venous ophthalmodynamometry is a valuable technique for the noninvasive assessment of ICP.

Entities:  

Mesh:

Year:  2011        PMID: 21529131     DOI: 10.3171/2011.3.JNS101275

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  16 in total

1.  Intracranial pressure modulates aqueous humour dynamics of the eye.

Authors:  Kayla R Ficarrotta; Christopher L Passaglia
Journal:  J Physiol       Date:  2020-01-09       Impact factor: 5.182

2.  Detection and characterization of tree shrew retinal venous pulsations: An animal model to study human retinal venous pulsations.

Authors:  Michael Dattilo; A Thomas Read; Brian C Samuels; C Ross Ethier
Journal:  Exp Eye Res       Date:  2019-06-06       Impact factor: 3.467

Review 3.  Non-invasive detection of intracranial pressure related to the optic nerve.

Authors:  Jian Li; Chao Wan
Journal:  Quant Imaging Med Surg       Date:  2021-06

Review 4.  The International Multi-disciplinary Consensus Conference on Multimodality Monitoring: future directions and emerging technologies.

Authors:  Paul Vespa; David Menon; Peter Le Roux
Journal:  Neurocrit Care       Date:  2014-12       Impact factor: 3.210

5.  The primary vascular dysregulation syndrome: implications for eye diseases.

Authors:  Josef Flammer; Katarzyna Konieczka; Andreas J Flammer
Journal:  EPMA J       Date:  2013-06-07       Impact factor: 6.543

6.  Safety and efficacy of combined epidural/general anesthesia during major abdominal surgery in patients with increased intracranial pressure: a cohort study.

Authors:  Igor Zabolotskikh; Nikita Trembach
Journal:  BMC Anesthesiol       Date:  2015-05-15       Impact factor: 2.217

7.  Was Terson's Tersons?

Authors:  Horace B Gardner
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2012

Review 8.  Noninvasive monitoring intracranial pressure - A review of available modalities.

Authors:  Marium Naveed Khan; Hussain Shallwani; Muhammad Ulusyar Khan; Muhammad Shahzad Shamim
Journal:  Surg Neurol Int       Date:  2017-04-05

Review 9.  Specialized Diagnostic Investigations to Assess Ocular Status in Hypertensive Diseases of Pregnancy.

Authors:  Rahul Navinchandra Bakhda
Journal:  Diseases       Date:  2016-04-22

10.  From head micro-motions towards CSF dynamics and non-invasive intracranial pressure monitoring.

Authors:  Arnošt Mládek; Václav Gerla; Petr Šeba; Vladimír Kolář; Petr Skalický; Helen Whitley; Lenka Lhotská; Vladimír Beneš; Ondřej Bradáč
Journal:  Sci Rep       Date:  2021-07-12       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.