Literature DB >> 21527109

Noninvasive polarimetric-based glucose monitoring: an in vivo study.

Georgeanne Purvinis1, Brent D Cameron, Douglas M Altrogge.   

Abstract

BACKGROUND: Since 1990, there has been significant research devoted toward development of a noninvasive physiological glucose sensor. In this article, we report on the use of optical polarimetry for the noninvasive measurement of physiological glucose concentration in the anterior chamber of the eye of New Zealand white (NZW) rabbits.
METHOD: Measurements were acquired using a custom-designed laser-based optical polarimetry system in a total of seven NZW rabbits anesthetized using an isoflurane-only anesthesia protocol. Aqueous humor-based polarimetric measurements were obtained by coupling light through the anterior chamber of the eye. Blood glucose levels were first stabilized and then altered with intravenous dextrose and insulin administration and measured every 3-5 min with a standard glucometer and intermittently with a YSI 2300 glucose analyzer. Acquired polarimetric glucose signals are calibrated to measured blood glucose concentration.
RESULTS: Based on a total of 41 data points, Clarke error grid analysis indicated 93% in zone A, 7% in zone B, and 0% in zones C and D, with reference concentrations between 93 and 521 mg/dl. Errors in prediction are shown to be related to gross movement of the rabbit during the procedures, incurring time-varying corneal birefringence effects that directly affect the measured polarimetric signal. These effects can be compensated for with appropriate design modifications.
CONCLUSIONS: An optical polarimetry technique was used for in vivo physiological glucose monitoring. The technique demonstrated provides a basis for the development of a noninvasive polarimetric glucose monitor for home, personal, or hospital use.
© 2011 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21527109      PMCID: PMC3125932          DOI: 10.1177/193229681100500227

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  16 in total

1.  Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study.

Authors:  Kirill V Larin; Massoud Motamedi; Taras V Ashitkov; Rinat O Esenaliev
Journal:  Phys Med Biol       Date:  2003-05-21       Impact factor: 3.609

2.  Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye.

Authors:  Justin S Baba; Brent D Cameron; Sangeeta Theru; Gerard L Coté
Journal:  J Biomed Opt       Date:  2002-07       Impact factor: 3.170

3.  Multicomponent blood analysis by near-infrared Raman spectroscopy.

Authors:  A J Berger; T W Koo; I Itzkan; G Horowitz; M S Feld
Journal:  Appl Opt       Date:  1999-05-01       Impact factor: 1.980

4.  Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach.

Authors:  B D Cameron; G L Cóte
Journal:  IEEE Trans Biomed Eng       Date:  1997-12       Impact factor: 4.538

5.  The use of polarized laser light through the eye for noninvasive glucose monitoring.

Authors:  B D Cameron; H W Gorde; B Satheesan; G L Coté
Journal:  Diabetes Technol Ther       Date:  1999       Impact factor: 6.118

6.  Measurement of the glucose transport time delay between the blood and aqueous humor of the eye for the eventual development of a noninvasive glucose sensor.

Authors:  B D Cameron; J S Baba; G L Coté
Journal:  Diabetes Technol Ther       Date:  2001       Impact factor: 6.118

7.  Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations.

Authors:  B Rabinovitch; W F March; R L Adams
Journal:  Diabetes Care       Date:  1982 May-Jun       Impact factor: 19.112

8.  The glucose content of the aqueous humour in man.

Authors:  S Pohjola
Journal:  Acta Ophthalmol (Copenh)       Date:  1966

Review 9.  Fluorescence-based glucose sensors.

Authors:  John C Pickup; Faeiza Hussain; Nicholas D Evans; Olaf J Rolinski; David J S Birch
Journal:  Biosens Bioelectron       Date:  2004-11-21       Impact factor: 10.618

10.  New optical scheme for a polarimetric-based glucose sensor.

Authors:  Rafat R Ansari; Stefan Böckle; Luigi Rovati
Journal:  J Biomed Opt       Date:  2004 Jan-Feb       Impact factor: 3.170

View more
  11 in total

1.  In vivo glucose monitoring using dual-wavelength polarimetry to overcome corneal birefringence in the presence of motion.

Authors:  Casey W Pirnstill; Bilal H Malik; Vincent C Gresham; Gerard L Coté
Journal:  Diabetes Technol Ther       Date:  2012-06-12       Impact factor: 6.118

2.  Continuous noninvasive monitoring of changes in human skin optical properties during oral intake of different sugars with optical coherence tomography.

Authors:  Yuqing Zhang; Guoyong Wu; Huajiang Wei; Zhouyi Guo; Hongqin Yang; Yonghong He; Shusen Xie; Ying Liu
Journal:  Biomed Opt Express       Date:  2014-02-28       Impact factor: 3.732

3.  Dual-wavelength polarimetric glucose sensing in the presence of birefringence and motion artifact using anterior chamber of the eye phantoms.

Authors:  Bilal H Malik; Casey W Pirnstill; Gerard L Coté
Journal:  J Biomed Opt       Date:  2013-01       Impact factor: 3.170

4.  Corneal birefringence measured by spectrally resolved Mueller matrix ellipsometry and implications for non-invasive glucose monitoring.

Authors:  Peter Westphal; Johannes-Maria Kaltenbach; Kai Wicker
Journal:  Biomed Opt Express       Date:  2016-03-07       Impact factor: 3.732

5.  Broadband polarimetric glucose determination in protein containing media using characteristic optical rotatory dispersion.

Authors:  Christian Stark; Cesar Andres Carvajal Arrieta; Reza Behroozian; Benjamin Redmer; Felix Fiedler; Stefan Müller
Journal:  Biomed Opt Express       Date:  2019-11-19       Impact factor: 3.732

6.  Label-Free Ultrasensitive Detection of Abnormal Chiral Metabolites in Diabetes.

Authors:  Yaoran Liu; Zilong Wu; Pavana Siddhartha Kollipara; Richard Montellano; Kumar Sharma; Yuebing Zheng
Journal:  ACS Nano       Date:  2021-03-24       Impact factor: 15.881

Review 7.  Review of Non-invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone.

Authors:  Maryamsadat Shokrekhodaei; Stella Quinones
Journal:  Sensors (Basel)       Date:  2020-02-25       Impact factor: 3.576

Review 8.  Non-Invasive Blood Glucose Monitoring Technology: A Review.

Authors:  Liu Tang; Shwu Jen Chang; Ching-Jung Chen; Jen-Tsai Liu
Journal:  Sensors (Basel)       Date:  2020-12-04       Impact factor: 3.576

Review 9.  Fiber Optic Sensors: A Review for Glucose Measurement.

Authors:  José Luis Cano Perez; Jaime Gutiérrez-Gutiérrez; Christian Perezcampos Mayoral; Eduardo L Pérez-Campos; Maria Del Socorro Pina Canseco; Lorenzo Tepech Carrillo; Laura Pérez-Campos Mayoral; Marciano Vargas Treviño; Edmundo López Apreza; Roberto Rojas Laguna
Journal:  Biosensors (Basel)       Date:  2021-02-25

10.  Noncontact Optical Measurement of Aqueous Humor Glucose Levels and Correlation with Serum Glucose Levels in Rabbit.

Authors:  Yih-Shiou Hwang; Eugene Yu-Chuan Kang; Chia-Rui Shen; Wei-Hsin Hong; Wei-Chi Wu
Journal:  Biosensors (Basel)       Date:  2021-10-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.