Literature DB >> 21526745

Structural correspondence between uranyl chloride complexes in solution and their stability constants.

L Soderholm1, S Skanthakumar, Richard E Wilson.   

Abstract

Pair-distribution functions (PDF)s were obtained from high-energy X-ray scattering (HEXS) data on a series of uranyl solutions as a function of chloride ion concentration. Analyses reveal that chloride forms only inner-sphere complexes with the uranyl, replacing inner-sphere waters such that the total uranyl coordination number decreases from 4.7 waters at [Cl(-)] = 0 m to 4.4 (1.7 water and 2.7 Cl(-)) at [Cl(-)] = 6.8 m. Some of the second-coordination sphere waters reorient upon uranyl inner-sphere chloride complexation in order to hydrogen bond with the bound anion. Similar data obtained on a series of solutions maintained at constant ionic strength are used to confirm structural assignments through determining stability constants for the addition of chloride to uranyl and comparison with published values. The stability constants, β(1) = 1.5(10) m(-1), β(2) = 0.8(4) m(-2), and β(3) = 0.4(1) m(-3), obtained in a series of solutions with constant ionic strength of 5.3 m, are in reasonable agreement with previously published results determined by solvent extraction. The agreement of stability constants supports our peak assignments for the PDF and thus our structural model for uranyl chloride complexes in solution. Using coordination numbers and speciation determined here as a function of chloride ion concentration, the monochloro species is found to have four coordinating waters in the uranyl equatorial plane, the dichoro species is found to be an equilibrium of three and two coordinating waters, and the trichloro species has only a single water in the equatorial plane. These values correspond to total average coordination numbers of 5, 4.3, and 4 for the mono-, di-, and trichlorouranyl complexes. From the equilibrium value of the dichloro species, it can be further estimated that ΔG = -0.5 kcal/mol for the conversion of five to four coordinate species. Overall, the HEXS data support the assertion that uranyl chloride correlations do exist and the results are not simply the result of solvent-ion effects.

Entities:  

Year:  2011        PMID: 21526745     DOI: 10.1021/jp111551t

Source DB:  PubMed          Journal:  J Phys Chem A        ISSN: 1089-5639            Impact factor:   2.781


  1 in total

1.  Stability of Studtite in Saline Solution: Identification of Uranyl-Peroxo-Halo Complex.

Authors:  Junyi Li; Zoltán Szabó; Mats Jonsson
Journal:  Inorg Chem       Date:  2022-05-24       Impact factor: 5.436

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.