Literature DB >> 21525684

Comparative evaluation of frictional characteristics of coated low friction ligatures - Super Slick Ties with conventional uncoated ligatures.

Deepu Leander1, Jyothindra K Kumar.   

Abstract

BACKGROUND: Elastomeric ligatures have constituted a versatile method of securing the archwire to bracket slot, though self-ligating brackets have been a recent innovation. Coating elastomeric ligatures with a hydrophobic polymeric substance has been suggested as a methodology in reducing friction at the archwire-bracket interface and in repelling salivary adherends. A new polymeric coated ligature tie - Super Slick Ties (SST), manufactured using Metafasix technology, has been marketed by TP laboratories for potential reduction in treatment time. AIM: The basic in vitro design is to compare the frictional characteristics of the coated ligatures with those of uncoated ligatures in four different archwires, namely, stainless steel, NiTi, TMA, and Timolium.
MATERIALS AND METHODS: Four archwires used are stainless steel archwires, TMA archwires, Timolium, NiTi archwires, and two types of elastomeric ligatures (the coated and uncoated ligatures) were used. The wires used were of 0.019 × 0.025 dimension. The evaluation of friction between the brackets and the archwire was carried out as per the test protocol described by Tidy. The values for kinetic friction were obtained and tabulated. Mean and standard deviation were calculated. Paired Student's "t" test was performed to analyze the significance of difference between means.
RESULTS: The results indicate a significant difference in friction produced when coated and conventional uncoated ligatures were used.
CONCLUSIONS: SST produced lower levels of friction (11%) for all archwire materials when compared to conventional uncoated ligatures (Dispense-A-Stix) and both conventional uncoated ligatures and coated ligatures gave a rank order of coefficient of kinetic friction (μkf) among archwires, with stainless steel archwires exhibiting the least and TMA TM showing the highest.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21525684     DOI: 10.4103/0970-9290.80004

Source DB:  PubMed          Journal:  Indian J Dent Res        ISSN: 0970-9290


  3 in total

Review 1.  Microbial Colonization on Elastomeric Ligatures during Orthodontic Therapeutics: An Overview.

Authors:  Rajesh Sawhney; Ravish Sharma; Kavita Sharma
Journal:  Turk J Orthod       Date:  2018-03-01

2.  The Effect of Ligature Type on Lateral Tooth Movement during Orthodontic Treatment with Lingual Appliances-An In Vitro Study.

Authors:  Elisabeth Reichardt; Steffen Decker; Michel Dalstra; Prasad Nalabothu; Markus Steineck; Leandro Fernandez; Carlalberta Verna
Journal:  Materials (Basel)       Date:  2022-05-07       Impact factor: 3.748

3.  Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study.

Authors:  Graziane Olímpio Pereira; Carla Maria Melleiro Gimenez; Lucas Prieto; Marcos Gabriel do Lago Prieto; Roberta Tarkany Basting
Journal:  Dental Press J Orthod       Date:  2016 Jul-Aug
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.