Literature DB >> 21520827

Ultrafast convolution/superposition using tabulated and exponential kernels on GPU.

Quan Chen1, Mingli Chen, Weiguo Lu.   

Abstract

PURPOSE: Collapsed-cone convolution/superposition (CCCS) dose calculation is the workhorse for IMRT dose calculation. The authors present a novel algorithm for computing CCCS dose on the modern graphic processing unit (GPU).
METHODS: The GPU algorithm includes a novel TERMA calculation that has no write-conflicts and has linear computation complexity. The CCCS algorithm uses either tabulated or exponential cumulative-cumulative kernels (CCKs) as reported in literature. The authors have demonstrated that the use of exponential kernels can reduce the computation complexity by order of a dimension and achieve excellent accuracy. Special attentions are paid to the unique architecture of GPU, especially the memory accessing pattern, which increases performance by more than tenfold.
RESULTS: As a result, the tabulated kernel implementation in GPU is two to three times faster than other GPU implementations reported in literature. The implementation of CCCS showed significant speedup on GPU over single core CPU. On tabulated CCK, speedups as high as 70 are observed; on exponential CCK, speedups as high as 90 are observed.
CONCLUSIONS: Overall, the GPU algorithm using exponential CCK is 1000-3000 times faster over a highly optimized single-threaded CPU implementation using tabulated CCK, while the dose differences are within 0.5% and 0.5 mm. This ultrafast CCCS algorithm will allow many time-sensitive applications to use accurate dose calculation.

Entities:  

Mesh:

Year:  2011        PMID: 21520827     DOI: 10.1118/1.3551996

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Current state of the art brachytherapy treatment planning dosimetry algorithms.

Authors:  P Papagiannis; E Pantelis; P Karaiskos
Journal:  Br J Radiol       Date:  2014-07-16       Impact factor: 3.039

2.  Parallel beamlet dose calculation via beamlet contexts in a distributed multi-GPU framework.

Authors:  Ryan Neph; Cheng Ouyang; John Neylon; Youming Yang; Ke Sheng
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

3.  Dosimetric evaluation of intensity-modulated radiotherapy, volumetric modulated arc therapy, and helical tomotherapy for hippocampal-avoidance whole brain radiotherapy.

Authors:  Yi Rong; Josh Evans; Meng Xu-Welliver; Cadron Pickett; Guang Jia; Quan Chen; Li Zuo
Journal:  PLoS One       Date:  2015-04-20       Impact factor: 3.240

4.  Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine.

Authors:  Jinhan Zhu; Lixin Chen; Along Chen; Guangwen Luo; Xiaowu Deng; Xiaowei Liu
Journal:  Radiat Oncol       Date:  2015-04-11       Impact factor: 3.481

5.  A virtual source model for Monte Carlo simulation of helical tomotherapy.

Authors:  Jiankui Yuan; Yi Rong; Quan Chen
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

6.  Preliminary study of clinical application on IMRT three-dimensional dose verification-based EPID system.

Authors:  Miaoyun Huang; David Huang; Jianping Zhang; Yuangui Chen; Benhua Xu; Lixin Chen
Journal:  J Appl Clin Med Phys       Date:  2017-06-08       Impact factor: 2.102

7.  Dosimetric validation and clinical implementation of two 3D dose verification systems for quality assurance in volumetric-modulated arc therapy techniques.

Authors:  Francisco Clemente-Gutiérrez; Consuelo Pérez-Vara
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Assessment of radiobiological metrics applied to patient-specific QA process of VMAT prostate treatments.

Authors:  Francisco Clemente-Gutiérrez; Consuelo Pérez-Vara; María H Clavo-Herranz; Concepción López-Carrizosa; José Pérez-Regadera; Carmen Ibáñez-Villoslada
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.