Literature DB >> 21519573

Clinical performance and material properties of single-implant overdenture attachment systems.

Nabeel H M Alsabeeha1, Michael V Swain, Alan G T Payne.   

Abstract

PURPOSE: The aim of this study was to evaluate the mechanical properties of different attachment systems used for mandibular single-implant overdentures and to compare their wear/deformation features with clinical performance in patients after 1 year.
MATERIALS AND METHODS: Three attachment systems were evaluated: large 5.9-mm titanium nitride-coated ball attachments with plastic matrices, standard 2.25-mm uncoated titanium alloy ball attachments with Dalla Bona-type gold alloy matrices, and Locator attachments of titanium nitride-coated patrices and nylon matrices. The hardness and elastic modulus of the systems were determined using the nanoindentation technique. Twelve attachments from each system were used in 36 edentulous patients to support mandibular single-implant overdentures. After 1 year, 5 samples from each system were retrieved and evaluated for wear changes under a scanning electron microscope.
RESULTS: The titanium nitride-coated patrices, regardless of system, appeared unchanged and did not require any maintenance. Extensive wear was evident in the uncoated titanium alloy patrices and Dalla Bona-type gold alloy matrices, resulting in high maintenance (15 activations). Minimal wear was observed in the plastic matrices with minimal maintenance (2 replacements). The Locator nylon matrices showed extensive deformation and deterioration with a substantial need for maintenance (16 replacements). The performance of the patrices was related to hardness, while that of the matrices was related to the creep response.
CONCLUSIONS: Large ball attachment systems of titanium nitride-coated patrices and plastic matrices reflect favorable wear behavior and clinical performance. These attachments are recommended for patients receiving mandibular single-implant overdentures.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21519573

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  12 in total

Review 1.  The single midline implant in the edentulous mandible: a systematic review.

Authors:  Nicole Passia; Matthias Kern
Journal:  Clin Oral Investig       Date:  2014-05-29       Impact factor: 3.573

2.  Immediate versus Delayed Attachment Incorporation Impact on Prosthetic Aftercare among Mandibular Implant-Supported Overdenture Wearers.

Authors:  Eran Zenziper; Ofir Rosner; Oded Ghelfan; Joseph Nissan; Sigalit Blumer; Gil Ben-Izhack; Moshe Davidovich; Liat Chaushu; Adrian Kahn; Sarit Naishlos
Journal:  J Clin Med       Date:  2022-06-19       Impact factor: 4.964

3.  Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-06-18

4.  Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study.

Authors:  Maryam Memarian; Simindokht Zarrati; Sedigheh Karimi; Mehran Bahrami
Journal:  J Dent (Tehran)       Date:  2018-03

5.  Cost-Effectiveness of CM-LOC Attachment versus Ball Attachment Retaining Single Implant Mandibular Overdentures.

Authors:  Amr Ahmed Naguib; Nada Sherin El Khourazaty; Ashraf Abd El Monaem
Journal:  Open Access Maced J Med Sci       Date:  2019-10-10

6.  Performance of attachments used in implant-supported overdentures: review of trends in the literature.

Authors:  Damian J Lee
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

7.  Comparison of changes in retentive force of three stud attachments for implant overdentures.

Authors:  Su-Min Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

8.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar

9.  Comparison of masticatory efficiency, patient satisfaction for single, two, and three implants supported overdenture in the same patient: A pilot study.

Authors:  Srinidhi Bhat; Ramesh Chowdhary; Sudhindra Mahoorkar
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

10.  Clinical performance of LOCATOR® attachments: A retrospective study with 1-8 years of follow-up.

Authors:  Christophe Guédat; Ursina Nagy; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2018-07-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.