Literature DB >> 21518674

First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography.

Takayuki Okamura1, Yoshinobu Onuma, Héctor M Garcia-Garcia, Robert-Jan M van Geuns, Joanna J Wykrzykowska, Carl Schultz, Willem J van der Giessen, Jurgen Ligthart, Evelyn Regar, Patrick W Serruys.   

Abstract

AIMS: The objective of this study is to evaluate the feasibility and safety of imaging human coronary arteries in vivo by optical frequency domain imaging (OFDI) in comparison to intravascular ultrasound (IVUS). OFDI has been recently developed to overcome the limitations of conventional time-domain optical coherence tomography (OCT), namely the need for proximal balloon occlusion. The Terumo-OFDI system is capable of acquiring images with high-speed automated pullback (up to 40 mm/sec) and requires only a short injection (3-4 sec) of small amount of x-ray contrast (9-16 ml). METHODS AND
RESULTS: Nineteen patients who underwent stent implantation were enrolled. IVUS/OFDI were performed before and after stenting. The incidences of any adverse event and angiographic adverse findings were recorded. Lumen area (LA) was measured by IVUS and OFDI at 1 mm intervals in the stented segments (n=19) as well as in the proximal, distal, and to-be-stented segments (n=40). In addition, lumen area in the stented segment was also measured by edge (E-) and video-densitometric (VD-) quantitative coronary angiography (QCA). The OFDI images were obtained without any adverse event related to imaging procedures. Post stenting (n=19), minimal LA (MLA) measured by OFDI (5.84 ± 1.89 mm2) was larger than that of E-QCA (4.16 ± 1.46 mm2, p<0.001) and VD-QCA (4.92 ± 1.55 mm2, p<0.05). It was smaller than IVUS-MLA (6.26 ± 2.01 mm2, N.S.) but the correlation between the two measurements was highly significant (R2=0.82, p<0.001).
CONCLUSIONS: The OFDI imaging is feasible both before and after stenting and has a promising safety profile. The OFDI provided clear high resolution images and robust lumen measurements.

Entities:  

Mesh:

Year:  2011        PMID: 21518674     DOI: 10.4244/EIJV6I9A182

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  22 in total

1.  Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography.

Authors:  Tianshi Wang; Tom Pfeiffer; Evelyn Regar; Wolfgang Wieser; Heleen van Beusekom; Charles T Lancee; Geert Springeling; Ilona Krabbendam; Antonius F W van der Steen; Robert Huber; Gijs van Soest
Journal:  Biomed Opt Express       Date:  2015-11-23       Impact factor: 3.732

2.  Cut-off value of mal-apposition volume and depth for resolution at early phase of acute incomplete stent apposition after CoCr-EES implantation.

Authors:  Yohei Uchimura; Tomonori Itoh; Hideto Oda; Yuya Taguchi; Wataru Sasaki; Kyosuke Kaneko; Tsubasa Sakamoto; Iwao Goto; Masafumi Sakuma; Masaru Ishida; Tatsuo Kikuchi; Daisuke Terashita; Hiromasa Otake; Yoshihiro Morino; Toshiro Shinke
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-29       Impact factor: 2.357

3.  In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound.

Authors:  Soo-Joong Kim; Hang Lee; Koji Kato; Taishi Yonetsu; Ik-Kyung Jang
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-06       Impact factor: 2.357

4.  High frame-rate intravascular optical frequency-domain imaging in vivo.

Authors:  Han Saem Cho; Sun-Joo Jang; Kyunghun Kim; Alexey V Dan-Chin-Yu; Milen Shishkov; Brett E Bouma; Wang-Yuhl Oh
Journal:  Biomed Opt Express       Date:  2013-12-16       Impact factor: 3.732

5.  Coronary plaque rupture with subsequent thrombosis typifies the culprit lesion of non-ST-segment-elevation myocardial infarction, not unstable angina: non-ST-segment-elevation acute coronary syndrome study.

Authors:  Mikumo Sakaguchi; Shoichi Ehara; Takao Hasegawa; Kenji Matsumoto; Satoshi Nishimura; Junichi Yoshikawa; Kenei Shimada
Journal:  Heart Vessels       Date:  2016-06-21       Impact factor: 2.037

6.  Invasive Imaging of Bioresorbable Coronary Scaffolds - A Review.

Authors:  Nienke S van Ditzhuijzen; Jurgen Mr Ligthart; Nico Bruining; Evelyn Regar; Heleen Mm van Beusekom
Journal:  Interv Cardiol       Date:  2013-03

7.  New insights into spotty calcification and plaque rupture in acute coronary syndrome: an optical coherence tomography study.

Authors:  Mikumo Sakaguchi; Takao Hasegawa; Shoichi Ehara; Kenji Matsumoto; Kazuki Mizutani; Tomokazu Iguchi; Hideshi Ishii; Masashi Nakagawa; Kenei Shimada; Minoru Yoshiyama
Journal:  Heart Vessels       Date:  2016-03-05       Impact factor: 2.037

8.  Otitis Media Middle Ear Effusion Identification and Characterization Using an Optical Coherence Tomography Otoscope.

Authors:  Diego Preciado; Ryan M Nolan; Radhika Joshi; Gina M Krakovsky; Anqi Zhang; Nickolas A Pudik; Nankee K Kumar; Ryan L Shelton; Stephen A Boppart; Nancy M Bauman
Journal:  Otolaryngol Head Neck Surg       Date:  2020-01-21       Impact factor: 3.497

9.  In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography.

Authors:  Shengxian Tu; Liang Xu; Jurgen Ligthart; Bo Xu; Karen Witberg; Zhongwei Sun; Gerhard Koning; Johan H C Reiber; Evelyn Regar
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-20       Impact factor: 2.357

Review 10.  Optical endomicroscopy and the road to real-time, in vivo pathology: present and future.

Authors:  Charles S Carignan; Yukako Yagi
Journal:  Diagn Pathol       Date:  2012-08-13       Impact factor: 2.644

View more