Literature DB >> 21518103

Prospective evaluation of the self-pressurized air-Q intubating laryngeal airway in children.

Narasimhan Jagannathan1, Lisa E Sohn, Ravinder Mankoo, Kenneth E Langen, Andrew G Roth, Steven C Hall.   

Abstract

OBJECTIVES: To assess the clinical efficacy of the self-pressurized air-Q ILA™ (ILA-SP). AIM: The purpose of this prospective audit was to evaluate the feasibility of the ILA-SP in clinical practice and generate data for future comparison trials.
BACKGROUND: The ILA-SP is a new first-generation supraglottic airway for children with a self-adjusting cuff and lack of a pilot balloon.
METHODS: Over a 4-month period, 352 children with an ASA physical status of I-III, newborn to 18 years of age, undergoing various procedures were studied. Data points assessed included insertion success rates, airway leak pressures, quality of ventilation, and perioperative complications associated with the use of this device.
RESULTS: In 349 of the 352 patients in this study, the ILA-SP was used successfully as a primary supraglottic airway device in a variety of patients. Three patients required conversion to a standard laryngeal mask airway or a tracheal tube. The mean initial airway leak pressure for all patients was 17.8 ± 5.4 cm H(2)O, and 20.4 ± 5.5 cm H(2)O when re-checked at 10 min, which was statistically significant (P < 0.001). Complications were limited to 14 patients and related to reflex activation of the airway (coughing, laryngospasm, and bronchospasm) (n = 10), sore throat (n = 3), and blood staining on removal of the device (n = 1). There were no episodes of regurgitation, aspiration, or hoarseness.
CONCLUSIONS: Acceptable clinical performance was demonstrated with the ILA-SP for a variety of procedures in infants and children with spontaneous and positive pressure ventilation. Future studies comparing this device to other supraglottic airways may provide useful information regarding the safety of the ILA-SP in pediatric clinical practice.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 21518103     DOI: 10.1111/j.1460-9592.2011.03576.x

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  6 in total

1.  Supraglottic airway devices in children.

Authors:  S Ramesh; R Jayanthi
Journal:  Indian J Anaesth       Date:  2011-09

Review 2.  Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis.

Authors:  Eun Jin Ahn; Geun Joo Choi; Hyun Kang; Chong Wha Baek; Yong Hun Jung; Young Cheol Woo; Si Ra Bang
Journal:  Biomed Res Int       Date:  2016-06-23       Impact factor: 3.411

3.  Comparison of laryngeal mask airway supremeTM as non-inflatable cuff device and self-pressurized air-QTM in children: Randomized controlled non-inferiority study.

Authors:  Jagyung Hwang; Boohwi Hong; Yoon-Hee Kim; Won Hyung Lee; Yumin Jo; SooKyoung Youn; Chae Seong Lim
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.817

4.  Clinical evaluation of Ambu® Aura-i™ - A new intubating laryngeal mask airway as an independent ventilatory device and a conduit for tracheal intubation in pediatric patients.

Authors:  Triveni M Rangaswamy; Avnish Bharadwaj; Priyanka Jain
Journal:  Int J Crit Illn Inj Sci       Date:  2019-12-11

5.  Comparison of success rate of intubation through Air-Q with ILMA using two different endotracheal tubes.

Authors:  S K Malhotra; K V Bharath; Vikas Saini
Journal:  Indian J Anaesth       Date:  2016-04

6.  Pediatric supraglottic airway devices in clinical practice: A prospective observational study.

Authors:  Maren Kleine-Brueggeney; Anne Gottfried; Sabine Nabecker; Robert Greif; Malte Book; Lorenz Theiler
Journal:  BMC Anesthesiol       Date:  2017-09-02       Impact factor: 2.217

  6 in total