Literature DB >> 21517992

Defining a significant stenosis in an autologous radio-cephalic arteriovenous fistula for hemodialysis.

Farzan Fahrtash1, Lukas Kairaitis, Simon Gruenewald, Tim Spicer, Hannah Sidrak, John Fletcher, Richard Allen, Jan Swinnen.   

Abstract

The current definition of a significant stenosis in an autologous arteriovenous fistula (aAVF), the percentage narrowing compared with the adjacent "normal" vessel, is inaccurate. We believe a significant stenosis in the aAVF is an absolute minimal luminal diameter determined by the requirements of the hemodialysis pump. To determine what absolute diameter constitutes a hemodynamically significant stenosis in a radio-cephalic autologous arteriovenous fistula (RC aAVF), the minimal luminal diameter of dysfunctional RC aAVF was compared to that of functional RC aAVF using grayscale and color ultrasound. There were 93 fistulas in study group and 77 in control group. The mean minimum luminal diameter in study group was significantly lower than in control group (2.19 vs. 4.71 mm, p 0.001). With a cutoff value of 2.7 mm, there was 90% sensitivity and 80% specificity in distinguishing functional fistula from dysfunctional fistula. The area under the receiver-operator curve was 90% (CI 84-94%), indicating that a 2.7 mm diameter is accurate in discriminating functional from dysfunctional fistulas. An absolute minimal luminal diameter of 2.7 mm, as determined with grayscale and color ultrasound, is a useful cutoff for defining significant stenosis in a RC aAVF.
© 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21517992     DOI: 10.1111/j.1525-139X.2011.00861.x

Source DB:  PubMed          Journal:  Semin Dial        ISSN: 0894-0959            Impact factor:   3.455


  4 in total

Review 1.  Combined functional and anatomical diagnostic endpoints for assessing arteriovenous fistula dysfunction.

Authors:  Ehsan Rajabi-Jaghargh; Rupak K Banerjee
Journal:  World J Nephrol       Date:  2015-02-06

2.  Maintaining a viable vascular access for hemodialysis in an elderly person with diabetes: a journey to live, not just to stay alive.

Authors:  Debi Cowan; Lindsay Smith; Josephine Chow
Journal:  Clin Case Rep       Date:  2016-01-04

3.  Measuring the palpable pulsatility length as a physical examination test in defining the severity of inflow stenosis for hemodialysis fistulas.

Authors:  Matt Chiung-Yu Chen; Mei-Jui Weng; Misoso Yi-Wen Wu; Yi-Chun Liu; Wen-Che Chi
Journal:  BMC Nephrol       Date:  2019-09-13       Impact factor: 2.388

Review 4.  Arteriovenous Hemodialysis Access Stenosis Diagnosed by Duplex Doppler Ultrasonography: A Review.

Authors:  Jan Malik; Cora de Bont; Anna Valerianova; Zdislava Krupickova; Ludmila Novakova
Journal:  Diagnostics (Basel)       Date:  2022-08-16
  4 in total