Comparison of Several Methods of Chromatographic Baseline Removal with a New Approach Based on Quantile Regression.

L Komsta1.   

Abstract

The article is intended to introduce and discuss a new quantile regression method for baseline detrending of chromatographic signals. It is compared with current methods based on polynomial fitting, spline fitting, LOESS, and Whittaker smoother, each with thresholding and reweighting approach. For curve flexibility selection in existing algorithms, a new method based on skewness of the residuals is successfully applied. The computational efficiency of all approaches is also discussed. The newly introduced methods could be preferred to visible better performance and short computational time. The other algorithms behave in comparable way, and polynomial regression can be here preferred due to short computational time.

Entities:  

Year:  2011        PMID: 21516139      PMCID: PMC3064906          DOI: 10.1007/s10337-011-1962-1

Source DB:  PubMed          Journal:  Chromatographia        ISSN: 0009-5893            Impact factor:   2.044


  5 in total

1.  Improved baseline recognition and modeling of FT NMR spectra

Authors: 
Journal:  J Magn Reson       Date:  2000-09       Impact factor: 2.229

2.  A perfect smoother.

Authors:  Paul H C Eilers
Journal:  Anal Chem       Date:  2003-07-15       Impact factor: 6.986

3.  Baseline correction using adaptive iteratively reweighted penalized least squares.

Authors:  Zhi-Min Zhang; Shan Chen; Yi-Zeng Liang
Journal:  Analyst       Date:  2010-02-19       Impact factor: 4.616

4.  A comparative study on several algorithms for denoising of thin layer densitograms.

Authors:  Łukasz Komsta
Journal:  Anal Chim Acta       Date:  2009-04-01       Impact factor: 6.558

5.  Median filtering for removal of low-frequency background drift.

Authors:  A W Moore; J W Jorgenson
Journal:  Anal Chem       Date:  1993-01-15       Impact factor: 6.986

  5 in total
  4 in total

1.  High-precision isothermal titration calorimetry with automated peak-shape analysis.

Authors:  Sandro Keller; Carolyn Vargas; Huaying Zhao; Grzegorz Piszczek; Chad A Brautigam; Peter Schuck
Journal:  Anal Chem       Date:  2012-05-14       Impact factor: 6.986

2.  A simple, robust orthogonal background correction method for two-dimensional liquid chromatography.

Authors:  Marcelo R Filgueira; Cecilia B Castells; Peter W Carr
Journal:  Anal Chem       Date:  2012-07-18       Impact factor: 6.986

3.  Response to Letter to the Editor Regarding: Comparison of Several Methods of Chromatographic Baseline Removal with a New Approach Based on Quantile Regression.

Authors:  L Komsta
Journal:  Chromatographia       Date:  2012-02-19       Impact factor: 2.044

4.  Collaborative Penalized Least Squares for Background Correction of Multiple Raman Spectra.

Authors:  Long Chen; Yingwen Wu; Tianjun Li; Zhuo Chen
Journal:  J Anal Methods Chem       Date:  2018-08-29       Impact factor: 2.193

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.