Literature DB >> 21515067

Acquired Von Willebrand syndrome is an early-onset problem in ventricular assist device patients.

Claudia Heilmann1, Ulrich Geisen, Friedhelm Beyersdorf, Lea Nakamura, Georg Trummer, Michael Berchtold-Herz, Christian Schlensak, Barbara Zieger.   

Abstract

OBJECTIVE: Acquired Von Willebrand syndrome (AVWS) can contribute to bleeding complications in patients with ventricular assist devices (VADs). AVWS results from shear stress, which causes unfolding of the high-molecular-weight (HMW) multimers of Von Willebrand factor (VWF) with subsequent cleavage. Loss of the HMW multimers of VWF is the leading finding in AVWS. In consequence, binding of VWF to collagen and to platelets is impaired. The onset of AVWS after VAD implantation is not yet determined. We examined VAD patients for presence of an AVWS in the early, intermediate, and late phase after VAD implantation.
METHODS: Patients with a biventricular Thoratec-PVAD(®) (BVAD, n = 6) or a left-ventricular HeartMateII(®) (HMII, n = 11) were analyzed prior to VAD implantation and after 1, 3, 14, 30, and 60 days. Diagnosis of AVWS based on VWF:ristocetin cofactor activity/VWF:VWF antigen (VWF:RCo/VWF:Ag), collagen-binding capacity:VWF antigen (VWF:CB/VWF:Ag), and multimeric analysis. In addition, we analyzed the number of bleeding episodes, which required surgical intervention.
RESULTS: No patient had an AVWS prior to VAD implantation. An AVWS was identified already in the very early postoperative period, that is, in almost all patients on the first day and in all patients on the third day. The AVWS was also detected in the majority of patients in the further course. Nine of all 17 patients suffered bleeding complications and required a total of 25 interventions due to hemorrhages. Forty percent of re-interventions were carried out within the first 10 days after implantation; five of these were necessary within the first 24h.
CONCLUSION: The AVWS is present already in the early postoperative phase after VAD implantation. Therefore, reduced shear stress has to be an important feature of newly developed assist devices in the future.
Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21515067     DOI: 10.1016/j.ejcts.2011.03.021

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  11 in total

Review 1.  [Intensive care treatment of patients with left ventricular assist devices].

Authors:  B Steinlechner; Daniel Zimpfer; Arno Schiferer; Nikolaus Heinrich; Thomas Schlöglhofer; Angela Rajek; Martin Dworschak; Michael Hiesmayr
Journal:  Med Klin Intensivmed Notfmed       Date:  2015-08-28       Impact factor: 0.840

2.  In vivo testing of a novel blood pump for short-term extracorporeal life support.

Authors:  Nicholas R Teman; David S Demos; Benjamin S Bryner; Bradley Faliks; Emilia M Jahangir; Daniel E Mazur; Alvaro Rojas-Pena; Robert H Bartlett; Jonathan W Haft
Journal:  Ann Thorac Surg       Date:  2014-05-22       Impact factor: 4.330

3.  Acquired von Willebrand syndrome in patients with extracorporeal life support (ECLS).

Authors:  Claudia Heilmann; Ulrich Geisen; Friedhelm Beyersdorf; Lea Nakamura; Christoph Benk; Georg Trummer; Michael Berchtold-Herz; Christian Schlensak; Barbara Zieger
Journal:  Intensive Care Med       Date:  2011-10-01       Impact factor: 17.440

4.  Bleeding in critical care associated with left ventricular assist devices: pathophysiology, symptoms, and management.

Authors:  F W G Leebeek; R Muslem
Journal:  Hematology Am Soc Hematol Educ Program       Date:  2019-12-06

Review 5.  Devices in the management of advanced, chronic heart failure.

Authors:  William T Abraham; Sakima A Smith
Journal:  Nat Rev Cardiol       Date:  2012-12-11       Impact factor: 32.419

Review 6.  Acquired von Willebrand syndrome associated with left ventricular assist device.

Authors:  Angelo Nascimbene; Sriram Neelamegham; O H Frazier; Joel L Moake; Jing-Fei Dong
Journal:  Blood       Date:  2016-05-03       Impact factor: 22.113

7.  Characterization of a pulsatile rotary total artificial heart.

Authors:  Patrick L Jurney; Jeremy J Glynn; Igor V Dykan; Matthew W Hagen; Sanjiv Kaul; Richard K Wampler; Monica T Hinds; George D Giraud
Journal:  Artif Organs       Date:  2020-10-14       Impact factor: 3.094

8.  Perioperative onset of acquired von Willebrand syndrome: Comparison between HVAD, HeartMate II and on-pump coronary bypass surgery.

Authors:  Christina Feldmann; Rashad Zayat; Andreas Goetzenich; Ali Aljalloud; Eva Woelke; Judith Maas; Lachmandath Tewarie; Thomas Schmitz-Rode; Ruediger Autschbach; Ulrich Steinseifer; Ajay Moza
Journal:  PLoS One       Date:  2017-02-24       Impact factor: 3.240

Review 9.  Complications of Continuous-Flow Mechanical Circulatory Support Devices.

Authors:  Harsh Patel; Raef Madanieh; Constantine E Kosmas; Satya K Vatti; Timothy J Vittorio
Journal:  Clin Med Insights Cardiol       Date:  2015-05-21

Review 10.  Hemostatic complications associated with ventricular assist devices.

Authors:  Talal Hilal; James Mudd; Thomas G DeLoughery
Journal:  Res Pract Thromb Haemost       Date:  2019-06-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.