Literature DB >> 21515041

A new impedimetric biosensor utilizing VEGF receptor-1 (Flt-1): early diagnosis of vascular endothelial growth factor in breast cancer.

Mustafa Kemal Sezgintürk1.   

Abstract

A new impedimetric biosensor, based on the use of vascular endothelial growth factor receptor-1 (VEGF-R1), was developed for the determination of vascular endothelial growth factor (VEGF). VEGF-R1 was immobilized through covalent coupling with 3-mercaptopropionic acid which formed a self-assembled monolayer on gold electrodes. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy techniques were employed to characterize the immobilization process and to detect VEGF. To successfully construct the biosensor current, experimental parameters were optimized. Kramers-Kronig Transform was performed on the experimental impedance data. The obtained results provided a linear response range from 10 to 70 pg/mL human VEGF. The applicability of the developed biosensor in the determination of VEGF in a spiked artificial human serum sample was experienced, yielding average recovery of 101%, in that order, with an average relative deviation value less than 5%.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21515041     DOI: 10.1016/j.bios.2011.03.025

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Nanostructured gold dsDNA sensor for early detection of breast cancer by beta protein 1 (BP1).

Authors:  Wanda I Pérez; Yarelys Soto; Jaime E Ramirez-Vick; Enrique Meléndez
Journal:  J Electroanal Chem (Lausanne)       Date:  2015-08-15       Impact factor: 4.464

2.  An origami paper-based nanoformulated immunosensor detects picograms of VEGF-C per milliliter of blood.

Authors:  Shuai Sun; Yang Wang; Tao Ming; Jinping Luo; Yu Xing; Juntao Liu; Ying Xiong; Yuanyuan Ma; Shi Yan; Yue Yang; Xinxia Cai
Journal:  Commun Biol       Date:  2021-01-26

Review 3.  Early lung cancer diagnosis by biosensors.

Authors:  Yuqian Zhang; Dongliang Yang; Lixing Weng; Lianhui Wang
Journal:  Int J Mol Sci       Date:  2013-07-25       Impact factor: 5.923

Review 4.  Non-Invasive Breast Cancer Diagnosis through Electrochemical Biosensing at Different Molecular Levels.

Authors:  Susana Campuzano; María Pedrero; José Manuel Pingarrón
Journal:  Sensors (Basel)       Date:  2017-08-31       Impact factor: 3.576

Review 5.  Screening and Biosensor-Based Approaches for Lung Cancer Detection.

Authors:  Lulu Wang
Journal:  Sensors (Basel)       Date:  2017-10-23       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.