A dosimetry method in the transverse plane of HDR Ir-192 brachytherapy source using gafchromic EBT2 film.

S C Uniyal1, S D Sharma, U C Naithani.   

Abstract

Radiochromic film dosimetry is increasingly used in brachytherapy applications for its higher resolution ability as compared to other experimental methods. The present study was aimed to assess the accuracy and suitability of use of the improved radiochromic film model, Gafchromic EBT2, to evaluate the dose distribution in the transverse plane of microselectron HDR (192)Ir source. A specially designed and locally fabricated Polymethyl methacrylate (PMMA) phantom was used in this work for the experimental measurement of dose distribution around the source in its transverse plane. The AAPM TG-43U1 recommended radial dose function, g (r), and dose rate constant, Λ, for the source were measured using Gafchromic EBT2 film and thermoluminescent dosimeters (TLD). The EBT2 film measured dosimetric quantities were validated against their values obtained from the TLD measurements and previously published values for the same source available in literature. The dose rate constant and radial dose function for microselectron HDR (192)Ir source obtained from Gafchromic EBT2 film measurements are in agreement with their TLD measured results within 3.9% and 2.8% respectively. They also agree within the accepted range of uncertainty with their experimental and Monte Carlo calculated results reported in literature. This work demonstrates the suitability of using Gafchromic EBT2 film dosimetry in characterization of dose distribution in the transverse plane of HDR Ir-192 source. This is a more efficient method than TLD dosimetry at discrete and distant positions. Relative to TLD dosimetry, it is found to be better reproducible, easy to use and a less expensive method of dosimetry. Copyright Â
© 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21507693     DOI: 10.1016/j.ejmp.2011.03.005

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  4 in total

1.  A study on comparison of Gafchromic EBT2 film response under single and cumulative exposure conditions.

Authors:  K Ganapathy; P G G Kurup; V Murali; M Muthukumaran; J Velmurugan
Journal:  J Med Phys       Date:  2013-10

2.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30

3.  High-Dose-Rate (192)Ir Brachytherapy Dose Verification: A Phantom Study.

Authors:  Alireza Nikoofar; Zohreh Hoseinpour; Seied Rabi Mahdavi; Hadi Hasanzadeh; Mostafa Rezaei Tavirani
Journal:  Iran J Cancer Prev       Date:  2015-05-22

4.  Quality Assurance Procedures based on Dosimetric, Gamma Analysis as a Fast Reliable Tool for Commissioning Brachytherapy Treatment Planning Systems.

Authors:  Grzegorz Zwierzchowski; Grzegorz Bieleda; Janusz Skowronek
Journal:  Radiol Oncol       Date:  2017-11-29       Impact factor: 2.991

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.