Literature DB >> 21507284

Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis.

Johannes Schmitt1, Manfred Wichmann, Matthias Karl, Matthias Göllner, Ulrich Lohbauer, Stefan Holst.   

Abstract

AIM: The aim of this prospective clinical trial was to evaluate the performance of zirconia-based all-ceramic posterior fixed partial dentures (FPDs) after 4 years of clinical use.
MATERIALS AND METHODS: Fifteen patients who needed 3- or 4-unit posterior FPDs were enrolled in the study. One manufacturer fabricated all restorations, following established clinical protocols and using computer-aided design/computer-aided manufacturing technology and one veneering material. Survival and success were evaluated clinically. Impressions were taken immediately after definitive cementation and after 48 months. Gold-coated epoxy replicas of the restorations were analyzed with scanning electron microscopy (SEM). Surface alterations were also evaluated clinically.
RESULTS: After 48 months, the survival rate for the FPDs was 100%. Three restorations exhibited minor chipping, for a fracture rate of 20% after 4 years. Thirty (59%) of the 51 individual restoration units revealed clinically rough occlusal surfaces, a finding that was confirmed by SEM.
CONCLUSION: The placement of 3- and 4-unit zirconia-based posterior FPDs can be considered a reliable treatment modality for medium-term clinical use. However, surface alterations of the veneering ceramics were observed after 4 years and are of notable clinical concern.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21507284

Source DB:  PubMed          Journal:  J Can Dent Assoc        ISSN: 0709-8936            Impact factor:   1.316


  3 in total

1.  Ten-year survival and chipping rates and clinical quality grading of zirconia-based fixed dental prostheses.

Authors:  Maren Teichmann; Anna Lena Wienert; Marcia Rückbeil; Volker Weber; Stefan Wolfart; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2018-03-08       Impact factor: 3.573

Review 2.  Do tooth-supported zirconia restorations present more technical failures related to fracture or loss of retention? Systematic review and meta-analysis.

Authors:  Carla Castiglia Gonzaga; Paula Pontes Garcia; Letícia Maíra Wambier; Fernanda Harumi Oku Prochnow; Luciano Madeira; Paulo Francisco Cesar
Journal:  Clin Oral Investig       Date:  2022-06-04       Impact factor: 3.606

3.  Evaluation of shear bond strength of zirconia to composite resin using different adhesive systems.

Authors:  Faramarz Zakavi; Mehrnoosh Mombeini; Sana Dibazar; Sarah Gholizadeh
Journal:  J Clin Exp Dent       Date:  2019-03-01
  3 in total