Literature DB >> 21506521

Reproducibility and robustness of a real-time microfluidic cell toxicity assay.

Gregory A Cooksey1, John T Elliott, Anne L Plant.   

Abstract

Numerous opportunities exist to apply microfluidic technology to high-throughput and high-content cell-based assays. However, maximizing the value of microfluidic assays for applications such as drug discovery, screening, or toxicity evaluation will require assurance of within-device repeatability, day-to-day reproducibility, and robustness to variations in conditions that might occur from laboratory to laboratory. This report describes a study of the performance and variability of a cell-based toxicity assay in microfluidic devices made of poly(dimethylsiloxane) (PDMS). The assay involves expression of destabilized green fluorescent protein (GFP) as a reporter of intracellular protein synthesis and degradation. Reduction in cellular GFP due to inhibition of ribosome activity by cycloheximide (CHX) was quantified with real-time quantitative fluorescence imaging. Assay repeatability was measured within a 64-chamber microfluidic device. Assay performance across a range of cell loading densities within a single device was assessed, as was replication of measurements in microfluidic devices prepared on different days. Assay robustness was tested using different fluorescence illumination sources and reservoir-to-device tubing choices. Both microfluidic and larger scale assay conditions showed comparable GFP decay rates upon CHX exposure, but the microfluidic data provided the higher level of confidence.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21506521     DOI: 10.1021/ac200273f

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Single-monomer formulation of polymerized polyethylene glycol diacrylate as a nonadsorptive material for microfluidics.

Authors:  Chad I Rogers; Jayson V Pagaduan; Gregory P Nordin; Adam T Woolley
Journal:  Anal Chem       Date:  2011-07-20       Impact factor: 6.986

2.  Vacuum-assisted cell loading enables shear-free mammalian microfluidic culture.

Authors:  Martin Kolnik; Lev S Tsimring; Jeff Hasty
Journal:  Lab Chip       Date:  2012-11-21       Impact factor: 6.799

3.  Multiparameter toxicity screening on a chip: Effects of UV radiation and titanium dioxide nanoparticles on HaCaT cells.

Authors:  Scott McCormick; Louise E Smith; Amy M Holmes; Ziqiu Tong; Enzo Lombi; Nicolas H Voelcker; Craig Priest
Journal:  Biomicrofluidics       Date:  2019-08-27       Impact factor: 2.800

4.  Intelligent acoustofluidics enabled mini-bioreactors for human brain organoids.

Authors:  Hongwei Cai; Zheng Ao; Zhuhao Wu; Sunghwa Song; Ken Mackie; Feng Guo
Journal:  Lab Chip       Date:  2021-06-01       Impact factor: 7.517

5.  How to Perform a Microfluidic Cultivation Experiment-A Guideline to Success.

Authors:  Sarah Täuber; Julian Schmitz; Luisa Blöbaum; Niklas Fante; Heiko Steinhoff; Alexander Grünberger
Journal:  Biosensors (Basel)       Date:  2021-11-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.