Literature DB >> 21504011

On-line reaction monitoring by extractive electrospray ionisation.

Bryan J McCullough1, Tony Bristow, Gavin O'Connor, Chris Hopley.   

Abstract

The design and development of a novel extractive electrospray ionisation (EESI) device for on-line reaction monitoring is described. The EESI apparatus uses a secondary, grounded nebuliser to produce an analyte aerosol and a Venturi pump is then used to transfer a sample of the aerosol to an electrospray source where it is ionised. The EESI apparatus was then tested with a variety of small, organic molecules to assess sensitivity, linearity and dynamic range. The performance of the technique will depend on the mass spectrometer used for the experiments; in the configurations used here it has a usable dynamic range of around 3.5 orders of magnitude with a linear range of around 2.5 orders of magnitude and is capable of analysing species present down to low µg/mL with signal-to-noise ratio greater than 2.5. The use of EESI for reaction monitoring was validated using a series of mock reaction mixtures and then used to monitor the base hydrolysis of ethyl salicylate to salicylic acid.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21504011     DOI: 10.1002/rcm.5016

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  5 in total

1.  Transient Ru-methyl formate intermediates generated with bifunctional transfer hydrogenation catalysts.

Authors:  Richard H Perry; Kristen R Brownell; Konstantin Chingin; Thomas J Cahill; Robert M Waymouth; Richard N Zare
Journal:  Proc Natl Acad Sci U S A       Date:  2012-02-06       Impact factor: 11.205

2.  On-line monitoring of continuous flow chemical synthesis using a portable, small footprint mass spectrometer.

Authors:  Tony W T Bristow; Andrew D Ray; Anne O'Kearney-McMullan; Louise Lim; Bryan McCullough; Alessio Zammataro
Journal:  J Am Soc Mass Spectrom       Date:  2014-08-09       Impact factor: 3.109

3.  Ultra-High-Throughput Acoustic Droplet Ejection-Open Port Interface-Mass Spectrometry for Parallel Medicinal Chemistry.

Authors:  Kenneth J DiRico; Wenyi Hua; Chang Liu; Joseph W Tucker; Anokha S Ratnayake; Mark E Flanagan; Matthew D Troutman; Mark C Noe; Hui Zhang
Journal:  ACS Med Chem Lett       Date:  2020-05-01       Impact factor: 4.345

Review 4.  The expanding role of electrospray ionization mass spectrometry for probing reactive intermediates in solution.

Authors:  Weitao Zhu; Yu Yuan; Peng Zhou; Le Zeng; Hua Wang; Ling Tang; Bin Guo; Bo Chen
Journal:  Molecules       Date:  2012-09-27       Impact factor: 4.411

5.  Direct detection of a sulfonate ester genotoxic impurity by atmospheric-pressure thermal desorption-extractive electrospray-mass spectrometry.

Authors:  Neil A Devenport; Laura C Sealey; Faisal H Alruways; Daniel J Weston; James C Reynolds; Colin S Creaser
Journal:  Anal Chem       Date:  2013-06-21       Impact factor: 6.986

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.