Quantitative determination of metabolization dynamics by a real-time 13CO2 breath test.

T Rubin1, T von Haimberger, A Helmke, K Heyne.   

Abstract

We have developed a flow-through fast liver investigation packet (FLIP) to quantitatively measure the amount of exhaled (13)CO(2), as a result of liver metabolization processes. The FLIP system allows investigation of every single breath in real time. Line width variations due to interactions with other gas components disturb traditional measurements and limit their sensitivity to the ppm range. Detection of the complete breath volume and the spectrally fully resolved line shape allows sensitivity in the ppb range with a standard deviation of approximately 80 ppb, a prerequisite to quantitatively analyze liver metabolization processes.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21502704     DOI: 10.1088/1752-7155/5/2/027102

Source DB:  PubMed          Journal:  J Breath Res        ISSN: 1752-7155            Impact factor:   3.262


  6 in total

1.  Gas-phase broadband spectroscopy using active sources: progress, status, and applications.

Authors:  Kevin C Cossel; Eleanor M Waxman; Ian A Finneran; Geoffrey A Blake; Jun Ye; Nathan R Newbury
Journal:  J Opt Soc Am B       Date:  2016-12-14       Impact factor: 2.106

2.  A novel variant of the 13C-methacetin liver function breath test that eliminates the confounding effect of individual differences in systemic CO2 kinetics.

Authors:  Hermann-Georg Holzhütter; Tilo Wuensch; Robert Gajowski; Nikolaus Berndt; Sascha Bulik; David Meierhofer; Martin Stockmann
Journal:  Arch Toxicol       Date:  2020-02-04       Impact factor: 5.153

3.  Gd-EOB-DTPA-enhanced T1 relaxometry for assessment of liver function determined by real-time 13C-methacetin breath test.

Authors:  Michael Haimerl; Irene Fuhrmann; Stefanie Poelsterl; Claudia Fellner; Marcel D Nickel; Kilian Weigand; Marc H Dahlke; Niklas Verloh; Christian Stroszczynski; Philipp Wiggermann
Journal:  Eur Radiol       Date:  2018-03-12       Impact factor: 5.315

4.  Assessment of the exhalation kinetics of volatile cancer biomarkers based on their physicochemical properties.

Authors:  Anton Amann; Pawel Mochalski; Vera Ruzsanyi; Yoav Y Broza; Hossam Haick
Journal:  J Breath Res       Date:  2014-02-24       Impact factor: 3.262

5.  Randomized clinical trial comparing liver resection with and without perioperative assessment of liver function.

Authors:  M Stockmann; F W R Vondran; R Fahrner; H M Tautenhahn; J Mittler; H Bektas; M Malinowski; M Jara; I Klein; J F Lock
Journal:  BJS Open       Date:  2018-06-14

6.  Porcine model for the study of liver regeneration enhanced by non-invasive 13C-methacetin breath test (LiMAx test) and permanent portal venous access.

Authors:  Eva-Maria Wittauer; Felix Oldhafer; Eva Augstein; Oliver Beetz; Moritz Kleine; Carsten Schumacher; Lion Sieg; Hendrik Eismann; Kai Johanning; André Bleich; Florian Wolfgang Rudolf Vondran
Journal:  PLoS One       Date:  2019-05-31       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.