Literature DB >> 21501966

Analysis of image sharpness reproducibility on a novel engineered micro-CT scanner with variable geometry and embedded recalibration software.

D Panetta1, N Belcari, A Del Guerra, A Bartolomei, P A Salvadori.   

Abstract

This study investigates the reproducibility of the reconstructed image sharpness, after modifications of the geometry setup, for a variable magnification micro-CT (μCT) scanner. All the measurements were performed on a novel engineered μCT scanner for in vivo imaging of small animals (Xalt), which has been recently built at the Institute of Clinical Physiology of the National Research Council (IFC-CNR, Pisa, Italy), in partnership with the University of Pisa. The Xalt scanner is equipped with an integrated software for on-line geometric recalibration, which will be used throughout the experiments. In order to evaluate the losses of image quality due to modifications of the geometry setup, we have made 22 consecutive acquisitions by changing alternatively the system geometry between two different setups (Large FoV - LF, and High Resolution - HR). For each acquisition, the tomographic images have been reconstructed before and after the on-line geometric recalibration. For each reconstruction, the image sharpness was evaluated using two different figures of merit: (i) the percentage contrast on a small bar pattern of fixed frequency (f = 5.5 lp/mm for the LF setup and f = 10 lp/mm for the HR setup) and (ii) the image entropy. We have found that, due to the small-scale mechanical uncertainty (in the order of the voxel size), a recalibration is necessary for each geometric setup after repositioning of the system's components; the resolution losses due to the lack of recalibration are worse for the HR setup (voxel size = 18.4 μm). The integrated on-line recalibration algorithm of the Xalt scanner allowed to perform the recalibration quickly, by restoring the spatial resolution of the system to the reference resolution obtained after the initial (off-line) calibration. Copyright Â
© 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 21501966     DOI: 10.1016/j.ejmp.2011.03.006

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  9 in total

1.  Piscivory in a Miocene Cetotheriidae of Peru: first record of fossilized stomach content for an extinct baleen-bearing whale.

Authors:  Alberto Collareta; Walter Landini; Olivier Lambert; Klaas Post; Chiara Tinelli; Claudio Di Celma; Daniele Panetta; Maria Tripodi; Piero A Salvadori; Davide Caramella; Damiano Marchi; Mario Urbina; Giovanni Bianucci
Journal:  Naturwissenschaften       Date:  2015-11-09

2.  3D fiber deposited polymeric scaffolds for external auditory canal wall.

Authors:  Carlos Mota; Mario Milazzo; Daniele Panetta; Luisa Trombi; Vera Gramigna; Piero A Salvadori; Stefano Giannotti; Luca Bruschini; Cesare Stefanini; Lorenzo Moroni; Stefano Berrettini; Serena Danti
Journal:  J Mater Sci Mater Med       Date:  2018-05-07       Impact factor: 3.896

3.  MicroPET/CT imaging of αvβ₃ integrin via a novel ⁶⁸Ga-NOTA-RGD peptidomimetic conjugate in rat myocardial infarction.

Authors:  Luca Menichetti; Claudia Kusmic; Daniele Panetta; Daniela Arosio; Debora Petroni; Marco Matteucci; Piero A Salvadori; Cesare Casagrande; Antonio L'Abbate; Leonardo Manzoni
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-05-15       Impact factor: 9.236

Review 4.  Micro-CT of rodents: state-of-the-art and future perspectives.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2014-06-26       Impact factor: 2.685

5.  Evaluation of the effect of a gamma irradiated DBM-pluronic F127 composite on bone regeneration in Wistar rat.

Authors:  Tamer Al Kayal; Daniele Panetta; Barbara Canciani; Paola Losi; Maria Tripodi; Silvia Burchielli; Priscilla Ottoni; Piero Antonio Salvadori; Giorgio Soldani
Journal:  PLoS One       Date:  2015-04-21       Impact factor: 3.240

6.  Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method.

Authors:  Claudio Chiastra; Eros Montin; Marco Bologna; Susanna Migliori; Cristina Aurigemma; Francesco Burzotta; Simona Celi; Gabriele Dubini; Francesco Migliavacca; Luca Mainardi
Journal:  PLoS One       Date:  2017-06-02       Impact factor: 3.240

7.  Comparative structural analysis of polyurethane and silicone catheters of totally implantable venous access devices by micro-computed tomography.

Authors:  Daniele Panetta; Lara Tollapi; Adriana Paolicchi; Elisa Marri; Giacomo Aringhieri; Davide Caramella
Journal:  SAGE Open Med       Date:  2021-12-03

8.  Erythro-Magneto-HA-Virosome: A Bio-Inspired Drug Delivery System for Active Targeting of Drugs in the Lungs.

Authors:  Alessio Vizzoca; Gioia Lucarini; Elisabetta Tognoni; Selene Tognarelli; Leonardo Ricotti; Lisa Gherardini; Gualtiero Pelosi; Mario Pellegrino; Arianna Menciassi; Settimio Grimaldi; Caterina Cinti
Journal:  Int J Mol Sci       Date:  2022-08-31       Impact factor: 6.208

9.  3D enamel thickness in Neandertal and modern human permanent canines.

Authors:  Laura Buti; Adeline Le Cabec; Daniele Panetta; Maria Tripodi; Piero A Salvadori; Jean-Jacques Hublin; Robin N M Feeney; Stefano Benazzi
Journal:  J Hum Evol       Date:  2017-09-21       Impact factor: 3.895

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.