Literature DB >> 21501400

Review of the dimensions of the median nerve and carpal tunnel using sonography in asymptomatic adults.

Betty Mani1, Radha Sarawagi, Rekha A Cherian.   

Abstract

OBJECTIVE: The study aims to establish the normal range of all sonologic measurements of carpal tunnel (CT) structures in an asymptomatic population.
METHODS: Sonological evaluation of 150 wrists in 75 asymptomatic adults was performed. The cross-sectional area (CSA) of the median nerve at four levels, the flattening ratio (FR) at three levels, the antero-posterior (AP) diameter of the CT and the distance of the transverse carpal ligament (TCL) from the trapezium-hamate (TmH) line were measured.
RESULTS: The mean (standard deviation (SD)) CSA of the median nerve at the distal forearm, CT inlet, mid and outlet were 6.8 (1.3), 7.4 (1.1), 7.5 (1.0), 7.1 (1.0) mm(2) , respectively. The mean (SD) FR at the CT inlet, mid and outlet were 2.66 (0.54), 2.55 (0.54), 3.69 (0.82), respectively. The mean (SD) AP diameter of the CT was 10.4 mm (1.1). Volar bowing of the retinaculum was seen in 7.3% of normal wrists.
CONCLUSIONS: The normal range at two SDs of the CSA of the median nerve at the inlet was 5.2-9.6 mm(2) . The upper limit of volar bowing of the flexor retinaculum was 0.8 mm. The FR overlaps with values obtained in other studies of patients with carpal tunnel syndrome. The mean AP diameter of the CT was 10.4 mm (SD 1.1). To the best of our knowledge, this is the largest study performed in an asymptomatic population assessing the different sonological parameters related to the CT.
© 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Mesh:

Year:  2011        PMID: 21501400     DOI: 10.1111/j.1754-9485.2010.02225.x

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  4 in total

1.  Quantification of human upper extremity nerves and fascicular anatomy.

Authors:  Natalie A Brill; Dustin J Tyler
Journal:  Muscle Nerve       Date:  2017-04-01       Impact factor: 3.217

2.  Ultrasonographic Measurement of Mean Cross-sectional Area of the Median Nerve in Pregnant Women in a Tertiary Level Hospital of Nepal: A Descriptive Cross-sectional Study.

Authors:  Govinda Adhikari; Prakash Kayastha; Sundar Suwal; Sharma Paudel; Dinesh Chataut; Santosh Maharjan; Ghanshyam Gurung
Journal:  JNMA J Nepal Med Assoc       Date:  2021-02-28       Impact factor: 0.406

3.  Reliability Assessment of Various Sonographic Techniques for Evaluating Carpal Tunnel Syndrome.

Authors:  Anthony D Junck; Eva M Escobedo; Bethany M Lipa; Michael Cronan; Colleen Anthonisen; Eduard Poltavskiy; Heejung Bang; Jay J Han
Journal:  J Ultrasound Med       Date:  2015-10-09       Impact factor: 2.153

4.  Sonographic diagnosis of carpal tunnel syndrome.

Authors:  Rodrigo O C Aguiar
Journal:  Radiol Bras       Date:  2015 Nov-Dec
  4 in total