| Literature DB >> 21501130 |
Y Fromes1, K Daghildjian, L Caumartin, M Fischer, I Rouquette, P Deleuze, O M Bical.
Abstract
The biocompatibility of minimal extracorporeal circuits has improved; however, anticoagulation is still required. We compared standard high-dose anticoagulation with a low-dose heparin regimen in a retrospective study of patients who underwent coronary bypass surgery using minimal cardiopulmonary bypass. One hundred patients who received 300 IU.kg(-1) heparin were compared with 68 patients who received heparin according to an individually adjusted activated coagulation time target of 300 s, resulting in a mean (SD) heparin dose of 145 (30) IU.kg(-1) . There were no thromboembolic events in either group; however, patients in the low-dose group had lower 24-hour mean (SD) postoperative blood loss than the conventional group (545 (61) vs 680 (88) ml, p=0.001) and a reduced rate of transfusion of allogeneic blood (15% patients transfused vs 32%, p=0.01). An individually tailored low-dose heparin regimen for minimal cardiopulmonary bypass is safe and may be associated with reduced bleeding and lower transfusion requirements.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21501130 DOI: 10.1111/j.1365-2044.2011.06709.x
Source DB: PubMed Journal: Anaesthesia ISSN: 0003-2409 Impact factor: 6.955