BACKGROUND: Detection of morphologic and volumetric changes in aneurysm necks is important when evaluating the effects of endovascular devices for aneurysm occlusion. PURPOSE: To optimize high-resolution 3D-TOF MRA at 4.7 T in order to achieve the best aneurysm-to-background contrast in experimental rat aneurysms, and to quantify the volume of the aneurysm neck by imaging. MATERIAL AND METHODS: Saccular aneurysms in the abdominal aorta of rats were coiled with platinum coils. Tissue relaxation times were measured, and used in a mathematical simulation. To optimize 3D-TOF angiography, imaging parameters were varied within the range obtained from the simulations. Tissue contrast and contrast-to-noise ratio were measured from MR images. TOF images were compared to conventional spin echo and gradient echo images and to endoscopic and histological analyses. RESULTS: Parameters yielding the best aneurysm-to-background contrast and contrast-to-noise ratio were determined. The agreement between the results from in vivo imaging and simulation was good. The optimized 3D-TOF MRA sequence (TR/TE/FA = 60 ms/6.6 ms/20°) had an isotropic voxel size of 117 µm, which enabled measurement of the aneurysm neck volume. CONCLUSION: High-resolution 3D-TOF angiography enables non-invasive quantification of changes in neck remnants of endovascularly coiled experimental aneurysms. In this model innovations like bioactive coils can be accurately tested for their efficacy for aneurysm occlusion.
BACKGROUND: Detection of morphologic and volumetric changes in aneurysm necks is important when evaluating the effects of endovascular devices for aneurysm occlusion. PURPOSE: To optimize high-resolution 3D-TOF MRA at 4.7 T in order to achieve the best aneurysm-to-background contrast in experimental rataneurysms, and to quantify the volume of the aneurysm neck by imaging. MATERIAL AND METHODS:Saccular aneurysms in the abdominal aorta of rats were coiled with platinum coils. Tissue relaxation times were measured, and used in a mathematical simulation. To optimize 3D-TOF angiography, imaging parameters were varied within the range obtained from the simulations. Tissue contrast and contrast-to-noise ratio were measured from MR images. TOF images were compared to conventional spin echo and gradient echo images and to endoscopic and histological analyses. RESULTS: Parameters yielding the best aneurysm-to-background contrast and contrast-to-noise ratio were determined. The agreement between the results from in vivo imaging and simulation was good. The optimized 3D-TOF MRA sequence (TR/TE/FA = 60 ms/6.6 ms/20°) had an isotropic voxel size of 117 µm, which enabled measurement of the aneurysm neck volume. CONCLUSION: High-resolution 3D-TOF angiography enables non-invasive quantification of changes in neck remnants of endovascularly coiled experimental aneurysms. In this model innovations like bioactive coils can be accurately tested for their efficacy for aneurysm occlusion.
Authors: Serge Marbacher; Johan Marjamaa; Essam Abdelhameed; Juha Hernesniemi; Mika Niemelä; Juhana Frösen Journal: J Vis Exp Date: 2014-10-12 Impact factor: 1.355