Literature DB >> 21498286

Usefulness of semi-automatic volumetry compared to established linear measurements in predicting lymph node metastases in MSCT.

Boris Buerke1, Joachim Gerss, Michael Puesken, Matthias Weckesser, Walter Heindel, Johannes Wessling.   

Abstract

BACKGROUND: Volumetry of lymph nodes potentially better reflect asymmetric size alterations independently of lymph node orientation in comparison to metric parameters (e.g. long-axis diameter).
PURPOSE: To distinguish between benign and malignant lymph nodes by comparing 2D and semi-automatic 3D measurements in MSCT.
MATERIAL AND METHODS: FDG-18 PET-CT was performed in 33 patients prior to therapy for malignant melanoma at stage III/IV. One hundred and eighty-six cervico-axillary, abdominal and inguinal lymph nodes were evaluated independently by two radiologists, both manually and with the use of semi-automatic segmentation software. Long axis (LAD), short axis (SAD), maximal 3D diameter, volume and elongation were obtained. PET-CT, PET-CT follow-up and/or histology served as a combined reference standard. Statistics encompassed intra-class correlation coefficients and ROC curves.
RESULTS: Compared to manual assessment, semi-automatic inter-observer variability was found to be lower, e.g. at 2.4% (95% CI 0.05-4.8) for LAD. The standard of reference revealed metastases in 90 (48%) of 186 lymph nodes. Semi-automatic prediction of lymph node metastases revealed highest areas under the ROC curves for volume (reader 1 0.77, 95%CI 0.64-0.90; reader 2 0.76, 95%CI 0.59-0.86) and SAD (reader 1 0.76, 95%CI 0.64-0.88; reader 2 0.75, 95%CI 0.62-0.89). The findings for LAD (reader 1 0.73, 95%CI 0.60-0.86; reader 2 0.71, 95%CI 0.71, 95%CI 0.57-0.85) and maximal 3D diameter (reader 1 0.70, 95%CI 0.53-0.86; reader 2 0.76, 95%CI 0.50-0.80) were found substantially lower and for elongation (reader 1 0.65, 95%CI 0.50-0.79; reader 2 0.66, 95%CI 0.52-0.81) significantly lower (p < 0.05).
CONCLUSION: Semi-automatic analysis of lymph nodes in malignant melanoma is supported by high segmentation quality and reproducibility. As compared to established SAD, semi-automatic lymph node volumetry does not have an additive role for categorizing lymph nodes as normal or metastatic in malignant melanoma.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21498286     DOI: 10.1258/ar.2011.100452

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

1.  Comparison of manual and semi-automatic measuring techniques in MSCT scans of patients with lymphoma: a multicentre study.

Authors:  A J Höink; J Weßling; R Koch; C Schülke; N Kohlhase; L Wassenaar; R M Mesters; M D'Anastasi; M Fabel; A Wulff; D Pinto dos Santos; A Kießling; A Graser; V Dicken; M Karpitschka; L Bornemann; W Heindel; B Buerke
Journal:  Eur Radiol       Date:  2014-09-06       Impact factor: 5.315

2.  [Accuracy and relevance of CT volumetry in open ocular injuries with intraocular foreign bodies].

Authors:  O A Maneschg; E Volek; Z Lohinai; M D Resch; A Papp; C Korom; K Karlinger; J Németh
Journal:  Ophthalmologe       Date:  2015-04       Impact factor: 1.059

3.  Ultrasound, CT, MRI, or PET-CT for staging and re-staging of adults with cutaneous melanoma.

Authors:  Jacqueline Dinnes; Lavinia Ferrante di Ruffano; Yemisi Takwoingi; Seau Tak Cheung; Paul Nathan; Rubeta N Matin; Naomi Chuchu; Sue Ann Chan; Alana Durack; Susan E Bayliss; Abha Gulati; Lopa Patel; Clare Davenport; Kathie Godfrey; Manil Subesinghe; Zoe Traill; Jonathan J Deeks; Hywel C Williams
Journal:  Cochrane Database Syst Rev       Date:  2019-07-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.