| Literature DB >> 21497645 |
Nitin Dixit1, Kevin M Maloney, Devendra S Kalonia.
Abstract
In this study, we have used quartz crystal microbalance (QCM) to quantitate the adsorption of a protein on silicone oil coated surfaces as a function of protein concentration, pH and ionic strength using a 5 MHz quartz crystal. Protein adsorption isotherms were generated at different solution pH and ionic strengths. Surface saturation concentrations were selected from adsorption isotherms and used to generate adsorption profiles from pH 3.0 to 9.0, and at ionic strengths of 10 mM and 150 mM. At low ionic strength (10mM) and pH 5.0 (close to the isoelectric point of the protein), maximum adsorption of protein to the silicone oil surface was observed. At higher ionic strength (150 mM), no significant pH influence on adsorption was observed. QCM could be used as a reliable technique to study the binding of proteins to silicone oil coated surfaces.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21497645 DOI: 10.1016/j.ijpharm.2011.03.062
Source DB: PubMed Journal: Int J Pharm ISSN: 0378-5173 Impact factor: 5.875