Haematological effect of pulsed ultrasound in acute muscular inflammation in rats.

Luis Ulisses Signori1, Silvio Teixeira da Costa, Adão Felix Saurin Neto, Rodrigo Machado Pizzolotto, Cristiane Beck, Graciele Sbruzzi, Antônio Marcos Vargas da Silva, Rodrigo Della Méa Plentz.   

Abstract

OBJECTIVE: To evaluate the effect of low-intensity pulsed ultrasound (LIPUS) on the haematological dynamics of an acute inflammatory process after an iatrogenic muscular lesion.
DESIGN: Controlled laboratory study.
SETTING: Research laboratory. PARTICIPANTS: Eighteen male Wistar rats (weight 350 to 450g) were submitted to surgical incision in the biceps femoris muscle (approximately 50%), and subsequently subdivided into control (n=9) and LIPUS (n=9) groups. INTERVENTION: Ultrasound (1.0MHz) was applied at the lesion site in the pulsed mode (2ms on, 8ms off) at 0.4W/cm(2) for 3 minutes at 1, 8 and 24 hours post-surgery. MAIN OUTCOME MEASURES: In these periods, blood was collected through venepuncture of the retro-orbital plexus and evaluated for different types of leukocytes and erythrocytes.
RESULTS: LIPUS reduced the total leukocyte count at 1, 8 and 24 hours post-surgery (1 hour, control 9017.2±481×10(3)/mm(3) vs LIPUS 6189.8±450×10(3)/mm(3); 8 hours, control 8078.2±501×10(3)/mm(3) vs LIPUS 5371.3±378×10(3)/mm(3); 24 hours, control 8192.3±646×10(3)/mm(3) vs LIPUS 6059.1±503×10(3)/mm(3); P<0.001). The monocyte count was reduced at 8 and 24 hours post-surgery (8 hours, control 815.5±126×10(3)/mm(3) vs LIPUS 375.4±70×10(3)/mm(3); 24 hours, control 875.3±124×10(3)/mm(3) vs LIPUS 564.7±56×10(3)/mm(3); P<0.001). The number of segmented neutrophils was only reduced at 1 hour post-surgery (control 5033.1±397×10(3)/mm(3) vs LIPUS 3594.8±191×10(3)/mm(3); P=0.006), and the lymphocyte count was only reduced at 8 hours post-surgery (control 4759.7±459×10(3)/mm(3) vs LIPUS 2584.1±356×10(3)/mm(3); P=0.003). Changes were not observed in the concentrations of young neutrophils, polibocytes and erythrocytes.
CONCLUSION: LIPUS reduced aspects of the inflammatory process following an acute incisional muscular lesion. Published by Elsevier Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 21497251     DOI: 10.1016/j.physio.2010.06.004

Source DB:  PubMed          Journal:  Physiotherapy        ISSN: 0031-9406            Impact factor:   3.358


  4 in total

1.  Effects of Low-Intensity Continuous Ultrasound on Hematological Parameters of Rats.

Authors:  M Mehrpour; A Shakeri-Zadeh; P Basir; B Jamei; H Ghaheri; M B Shiran
Journal:  J Biomed Phys Eng       Date:  2016-09-01

2.  Experimental Verification of Modeled Thermal Distribution Produced by a Piston Source in Physiotherapy Ultrasound.

Authors:  M I Gutierrez; S A Lopez-Haro; A Vera; L Leija
Journal:  Biomed Res Int       Date:  2016-11-23       Impact factor: 3.411

3.  Why we should care about soft tissue interfaces when applying ultrasonic diathermy: an experimental and computer simulation study.

Authors:  Thaís Pionório Omena; Aldo José Fontes-Pereira; Rejane Medeiros Costa; Ricardo Jorge Simões; Marco Antônio von Krüger; Wagner Coelho de Albuquerque Pereira
Journal:  J Ther Ultrasound       Date:  2017-01-27

4.  The effect of low-intensity pulsed ultrasound on bone-tendon junction healing: Initiating after inflammation stage.

Authors:  Hongbin Lu; Feifei Liu; Huabin Chen; Can Chen; Jin Qu; Daqi Xu; Tao Zhang; Jingyong Zhou; Jianzhong Hu
Journal:  J Orthop Res       Date:  2016-02-18       Impact factor: 3.494