Bacterial-sized particle inflow through sutured clear corneal incisions in a laboratory human model.

William N May1, Juan Castro-Combs, Renata T Kashiwabuchi, Hans Hertzog, Woranart Tattiyakul, Yasin A Kahn, Flavio Hirai, Emily W Gower, Ashley Behrens.   

Abstract

PURPOSE: To determine the effectiveness of a single radial suture placement in 2 clear corneal incision (CCI) configurations in preventing inflow of bacterial-sized particles.
SETTING: Wilmer Eye Institute, Baltimore, Maryland, USA.
DESIGN: Experimental study.
METHODS: Ten human globes were used. Two 25-gauge needles connected to a saline solution bag and to a digital manometer were inserted through the limbus 120 degrees apart. Four incision-suture combinations were evaluated sequentially in each cornea. All incisions had the same dimensions (2.75 mm width, 3.00 mm length). Two incisions were single plane, and 2 were biplane. One incision from each configuration was left unsutured, and the other was sutured (10-0 nylon). With a preset 10 mm Hg intraocular pressure (IOP), India ink was applied to the incision site and a sudden IOP fluctuation was induced. Inflow was outlined and measured by planimetry.
RESULTS: There was a significant increase in area and linear distance of India-ink inflow after pressure challenge in all groups (P < .05), but with important differences among them. When the sutured and unsutured groups from each CCI were compared, there was a significantly smaller area of inflow in the 2-step unsutured group (P < .05). The linear inflow was higher in both sutured groups; however, the difference was significant for the 2-step incision configuration only (P < .05).
CONCLUSIONS: A single radial suture reduced the area of inflow of bacterial-sized particles but increased the linear distance of inflow in single-plane 3.0 mm incisions. Suture placement in a stepped incision increased inflow of bacterial-sized particles. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2011. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21497050     DOI: 10.1016/j.jcrs.2010.11.042

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

Review 1.  Cataract surgery and methods of wound closure: a review.

Authors:  Cynthia Matossian; Sarah Makari; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-05-22

2.  Hydrogel Sealant for Closure of Clear Corneal Incisions in Combined Glaucoma Procedures.

Authors:  Ryan D Machiele; Abhilash Guduru; Leon W Herndon
Journal:  Clin Ophthalmol       Date:  2022-03-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.