Literature DB >> 21496179

Reproducibility of esophageal high-resolution manometry.

A Bogte1, A J Bredenoord, J Oors, P D Siersema, A J P M Smout.   

Abstract

BACKGROUND: Esophageal high-resolution manometry (HRM) is a novel method for esophageal function testing that has prompted the development of new parameters for quantitative analysis of esophageal function. Until now, the reproducibility of these parameters has not been investigated.
METHODS: Twenty healthy volunteers underwent HRM on two separate days. Standard HRM parameters were measured. In addition, in conventional (virtual) line tracings, lower esophageal sphincter (LES) resting pressure, relaxation pressure, and relative relaxation pressure were measured. Firstly, for each variable, the mean percentage of covariation (100×SD/mean: %COV) was derived as a measure of inter- and intra-individual variation. Secondly, Kendall's coefficients of concordance (W values) were calculated. Thirdly, Bland-Altman plots were used to express concordance graphically. KEY
RESULTS: Statistically significant concordance values were found for upper esophageal sphincter (UES) pressure (W=0.90, P=0.02), transition zone length (W=0.92, P=0.01), LES length (W=0.81, P=0.04), LES pressure (W=0.75, P=0.05), LES relaxation pressure (W=0.75, P=0.03), relative LES relaxation pressure (W=0.78, P=0.05), gastric pressure (W=0.81, P=0.04), and contraction amplitude 5cm above the LES (W=0.86, P=0.03). In conventional setting, only LES resting pressure (W=0.835, P=0.03) proved significant. In HRM tracings, concordance values for contraction wave parameters, and in conventional line tracings, LES relaxation pressure and relative relaxation pressure did not reach levels of statistical significance. CONCLUSIONS & INFERENCES: Esophageal HRM yields reproducible results. Parameters that represent anatomic structures show better reproducibility than contraction wave parameters. The reproducibility of LES resting and relaxation pressure assessed with HRM is better than with conventional manometry and further supports the clinical use of HRM.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 21496179     DOI: 10.1111/j.1365-2982.2011.01713.x

Source DB:  PubMed          Journal:  Neurogastroenterol Motil        ISSN: 1350-1925            Impact factor:   3.598


  16 in total

1.  Can high resolution manometry parameters for achalasia be obtained by conventional manometry?

Authors:  Fernando Am Herbella; Marco G Patti
Journal:  World J Gastrointest Pathophysiol       Date:  2015-08-15

2.  Comparison of two high-resolution manometry software systems in evaluating esophageal motor function.

Authors:  A Rengarajan; J Drapekin; A Patel; C P Gyawali
Journal:  Neurogastroenterol Motil       Date:  2016-06-28       Impact factor: 3.598

3.  Significant pressure differences between solid-state and water-perfused systems in lower esophageal sphincter measurement.

Authors:  Philipp Gehwolf; Ronald A Hinder; Kenneth R DeVault; Michael Edlinger; Heinz F Wykypiel; Paul J Klingler
Journal:  Surg Endosc       Date:  2015-02-21       Impact factor: 4.584

Review 4.  Current status of achalasia management: a review on diagnosis and treatment.

Authors:  Joshua Tuason; Haruhiro Inoue
Journal:  J Gastroenterol       Date:  2017-02-10       Impact factor: 7.527

5.  Electrical bioimpedance and other techniques for gastric emptying and motility evaluation.

Authors:  María Raquel Huerta-Franco; Miguel Vargas-Luna; Juana Berenice Montes-Frausto; Corina Flores-Hernández; Ismael Morales-Mata
Journal:  World J Gastrointest Pathophysiol       Date:  2012-02-15

6.  Characterization of Esophageal Motility Disorders in Children Presenting With Dysphagia Using High-Resolution Manometry.

Authors:  Francis Edeani; Adeel Malik; Ajay Kaul
Journal:  Curr Gastroenterol Rep       Date:  2017-03

7.  The relationship between gastroesophageal junction integrity and symptomatic fundoplication outcomes.

Authors:  Brexton Turner; Melissa Helm; Emily Hetzel; Max Schumm; Jon C Gould
Journal:  Surg Endosc       Date:  2019-06-18       Impact factor: 4.584

8.  High-Resolution Manometry Improves the Diagnosis of Esophageal Motility Disorders in Patients With Dysphagia: A Randomized Multicenter Study.

Authors:  Sabine Roman; Laure Huot; Frank Zerbib; Stanislas Bruley des Varannes; Guillaume Gourcerol; Benoit Coffin; Alain Ropert; Adeline Roux; François Mion
Journal:  Am J Gastroenterol       Date:  2016-02-02       Impact factor: 10.864

Review 9.  Clinical applications of esophageal impedance monitoring and high-resolution manometry.

Authors:  Boudewijn F Kessing; André J P M Smout; Albert J Bredenoord
Journal:  Curr Gastroenterol Rep       Date:  2012-06

10.  A comparative study of 22-channel water-perfusion system and solid-state system with 36-sensors in esophageal manometery.

Authors:  Kun Wang; Li-Ping Duan; Ying Ge; Zhi-Wei Xia; Zhi-Jie Xu
Journal:  BMC Gastroenterol       Date:  2012-11-07       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.