Literature DB >> 21496135

Comparison of Celox-A, ChitoFlex, WoundStat, and combat gauze hemostatic agents versus standard gauze dressing in control of hemorrhage in a swine model of penetrating trauma.

Lanny F Littlejohn1, John J Devlin, Sara S Kircher, Robert Lueken, Michael R Melia, Andrew S Johnson.   

Abstract

OBJECTIVES: Uncontrolled hemorrhage remains one of the leading causes of trauma deaths and one of the most challenging problems facing emergency medical professionals. Several hemostatic agents have emerged as effective adjuncts in controlling extremity hemorrhage. However, a review of the current literature indicates that none of these agents have proven superior under all conditions and in all wound types. This study compared several hemostatic agents in a lethal penetrating groin wound model where the bleeding site could not be visualized.
METHODS: A complex groin injury with a small penetrating wound, followed by transection of the femoral vessels and 45 seconds of uncontrolled hemorrhage, was created in 80 swine. The animals were then randomized to five treatment groups (16 animals each). Group 1 was Celox-A (CA), group 2 was combat gauze (CG), group 3 was Chitoflex (CF), group 4 was WoundStat (WS), and group 5 was standard gauze (SG) dressing. Each agent was applied with 5 minutes of manual pressure. Hetastarch (500 mL) was infused over 30 minutes. Hemodynamic parameters were recorded over 180 minutes. Primary endpoints were attainment of initial hemostasis and incidence of rebleeding.
RESULTS: Overall, no difference was found among the agents with respect to initial hemostasis, rebleeding, and survival. Localizing effects among the granular agents, with and without delivery mechanisms, revealed that WS performed more poorly in initial hemostasis and survival when compared to CA.
CONCLUSIONS: In this swine model of uncontrolled penetrating hemorrhage, SG dressing performed similarly to the hemostatic agents tested. This supports the concept that proper wound packing and pressure may be more important than the use of a hemostatic agent in small penetrating wounds with severe vascular trauma.
© 2011 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21496135     DOI: 10.1111/j.1553-2712.2011.01036.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  11 in total

Review 1.  Topical and effective hemostatic medicines in the battlefield.

Authors:  Yin-Juan Zhang; Bo Gao; Xi-Wen Liu
Journal:  Int J Clin Exp Med       Date:  2015-01-15

2.  Comparison of the topical haemostatic efficacy of nano-micro particles of clinoptilolite and kaolin in a rat model of haemorrhagic injury.

Authors:  A Bayır; M Eryılmaz; M Demirbilek; E B Denkbaş; I Arzıman; M Durusu
Journal:  Eur J Trauma Emerg Surg       Date:  2015-03-14       Impact factor: 3.693

3.  A shape memory foam composite with enhanced fluid uptake and bactericidal properties as a hemostatic agent.

Authors:  T L Landsman; T Touchet; S M Hasan; C Smith; B Russell; J Rivera; D J Maitland; E Cosgriff-Hernandez
Journal:  Acta Biomater       Date:  2016-10-06       Impact factor: 8.947

Review 4.  [Hemostyptics for treatment of junctional vascular injuries : Management of traumatic vascular injuries at the transition from trunk to extremities].

Authors:  D C Hinck; S Wipper; E S Debus
Journal:  Unfallchirurg       Date:  2018-07       Impact factor: 1.000

Review 5.  Hemostatic strategies for traumatic and surgical bleeding.

Authors:  Adam M Behrens; Michael J Sikorski; Peter Kofinas
Journal:  J Biomed Mater Res A       Date:  2013-12-12       Impact factor: 4.396

6.  Celox-coated gauze for the treatment of civilian penetrating trauma: a randomized clinical trial.

Authors:  Hamid Reza Hatamabadi; Fatemeh Asayesh Zarchi; Hamid Kariman; Ali Arhami Dolatabadi; Ali Tabatabaey; Afshin Amini
Journal:  Trauma Mon       Date:  2015-01-20

7.  Efficacy and safety of damage control in experimental animal models of injury: protocol for a systematic review and meta-analysis.

Authors:  Nela Cosic; Derek J Roberts; Henry T Stelfox
Journal:  Syst Rev       Date:  2014-11-22

8.  The iTClamp controls junctional bleeding in a lethal swine exsanguination model.

Authors:  Dennis Filips; Sarvesh Logsetty; Jonathan Tan; Ian Atkinson; Kelly Mottet
Journal:  Prehosp Emerg Care       Date:  2013-08-22       Impact factor: 3.077

9.  Comparison of Topical Hemostatic Agents in a Swine Model of Extremity Arterial Hemorrhage: BloodSTOP iX Battle Matrix vs. QuikClot Combat Gauze.

Authors:  Huixi Li; Lin Wang; Amjad Alwaal; Yung-Chin Lee; Amanda Reed-Maldonado; Taylor A Spangler; Lia Banie; Reginald B O'Hara; Guiting Lin
Journal:  Int J Mol Sci       Date:  2016-04-12       Impact factor: 5.923

10.  Efficacy of a chitosan tampon in the loop electrosurgical excision procedure: A prospective randomized controlled study.

Authors:  Gun Oh Chong; Yoon Hee Lee; Se Young Jeon; Hee-Young Yang; Sang-Hyun An
Journal:  Sci Rep       Date:  2020-04-07       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.