Comparative study of two laser Doppler blood flowmeters.

N J Barnett1, G Dougherty, S J Pettinger.   

Abstract

A new infrared laser Doppler blood flow instrument (Moor MBF3D) was evaluated using an in vitro model allowing measurements over a range of flow velocities and concentrations. The responses correlated well (r = 0.96, p less than 0.01) with those obtained simultaneously using a Perimed PF3 laser Doppler instrument. The different processing bandwidths of the instruments were investigated and the wideband mode of operation is recommended for flow measurements where there may be fast moving red blood cells (rbcs). The infrared instrument is capable of dual-channel operation, and the two channels are shown to respond almost identically for similar changes in blood flow through the in vitro model (r = 0.999, p less than 0.01). The main advantage of the dual-channel instrument is that continuous measurements may be made simultaneously at two different skin sites allowing dynamic flow responses to be compared.

Mesh:

Year:  1990        PMID: 2149392     DOI: 10.3109/03091909009015431

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  7 in total

Review 1.  Review of methodological developments in laser Doppler flowmetry.

Authors:  Vinayakrishnan Rajan; Babu Varghese; Ton G van Leeuwen; Wiendelt Steenbergen
Journal:  Lasers Med Sci       Date:  2008-01-31       Impact factor: 3.161

2.  Laser Doppler measurements of inner ear blood flow during experimental thrombosis of cochlear blood vessels in the guinea pig.

Authors:  F Scheibe; H Haupt; H Grunert
Journal:  Eur Arch Otorhinolaryngol       Date:  1997       Impact factor: 2.503

3.  Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits.

Authors:  R Bray; K Forrester; J J McDougall; A Damji; W R Ferrell
Journal:  Med Biol Eng Comput       Date:  1996-05       Impact factor: 2.602

4.  In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: measurement in knee ligaments of adult rabbits.

Authors:  K Forrester; M Doschak; R Bray
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

5.  Reduced arteriovenous shunting capacity after local heating and redistribution of baseline skin blood flow in type 2 diabetes assessed with velocity-resolved quantitative laser Doppler flowmetry.

Authors:  Ingemar Fredriksson; Marcus Larsson; Fredrik H Nyström; Toste Länne; Carl J Ostgren; Tomas Strömberg
Journal:  Diabetes       Date:  2010-04-14       Impact factor: 9.461

6.  Dental pulp testing: a review.

Authors:  Eugene Chen; Paul V Abbott
Journal:  Int J Dent       Date:  2009-11-12

7.  Local inhibition of nitric oxide generation in man reduces blood flow in finger pulp but not in hand dorsum skin.

Authors:  J P Noon; W G Haynes; D J Webb; A C Shore
Journal:  J Physiol       Date:  1996-01-15       Impact factor: 5.182

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.