Abstract

OBJECTIVE: To report an accurate complication rate in pediatric osseointegrated implants in a large cohort of patients from a major center and to characterize the complications observed.
SETTING: Tertiary care pediatric hospital. STUDY
DESIGN: Case series with chart review of all consecutive patients receiving otologic osseointegrated implants at Cincinnati Children's Hospital since 2001. SUBJECTS AND METHODS: All patients undergoing osseointegrated implant placement were identified at Cincinnati Children's Hospital, and complication rates were tabulated and stratified to major and minor based on the need for surgical revision. Evaluations of syndromic and body mass index associations were performed, along with evaluation of length of follow-up.
RESULTS: Forty-three patients were identified with 88 implants placed. Eighteen (42%) children had a diagnosis of a craniofacial syndrome. Overall, 19 (41.9%) returned to the operating suite, with a complication rate of 46.1%. A long duration of follow-up was obtained, and with this was identified an increasing risk of complications over time. Also identified was a significantly increased complication risk associated with a craniofacial syndrome. Body mass index was not found to be associated with complications.
CONCLUSION: Osseointegrated implants require frequent maintenance care from the surgeon. Complication rates are higher for children with a diagnosis of a craniofacial syndrome, and the risk of a complication increases significantly over a prolonged period of time.

Entities:  

Mesh:

Year:  2011        PMID: 21493240     DOI: 10.1177/0194599810397747

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497


  2 in total

1.  Surgical Solution for the Transformation of the Percutaneous Bone Anchored Hearing Aid to a Transcutaneous System in Complicated Cases.

Authors:  Zsofia Bere; Gabor Vass; Adam Perenyi; Zoltan Tobias; Laszlo Rovo
Journal:  J Int Adv Otol       Date:  2020-12       Impact factor: 1.017

2.  Laser-Doppler microvascular measurements in the peri-implant areas of different osseointegrated bone conductor implant systems.

Authors:  János Jarabin; Zsófia Bere; Petra Hartmann; Ferenc Tóth; József Géza Kiss; László Rovó
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-12       Impact factor: 2.503

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.