Abstract

PURPOSE: To compare the volumetric misfit between implant restorative platforms of implants and implant frameworks manufactured with two different technologies. One set of implant frameworks was made with a CAD/CAM protocol and a tactile probe; the second protocol consisted of frameworks made with the lost-wax technique and conventional casting technology.
MATERIALS AND METHODS: In this laboratory study, an acrylic resin model with five "inter-foraminal" implants was used as the "patient" model. Implant level impressions were made, and 10 definitive master casts were fabricated. The casts were verified using an index made on the patient model. Five cast high palladium noble alloy and five CAD/CAM titanium alloy frameworks were fabricated. The patient's implants and the frameworks' implant restorative platforms were scanned with a tactile probe, and the data were digitized. The digitized implant restorative platforms of the frameworks were fit onto the patient's digitized implants via a software program, in a process called "lofting." This computerized procedure simulated a 1-screw test; the process was performed on both sides. The volumetric misfit between the implant restorative platforms of the frameworks and the patient's implants were measured. A Welch's t-test was used to determine significant differences (p < 0.05) between the misfit of the two technologies. Wilcoxon Signed-Rank tests were used to evaluate differences between the right and left sides.
RESULTS: On average, the volumetric misfit of the CAD/CAM frameworks was 1.8 mm(3) less than the volumetric misfit of the cast alloy frameworks (p < 0.05). The Wilcoxon Signed-Rank tests showed no significant differences between the right and left sides within both systems (p > 0.05).
CONCLUSIONS: The scanning technology and computer software program used in this study demonstrated that the CAD/CAM implant frameworks had statistically significantly less volumetric misfit when compared with the cast implant frameworks. There were no significant differences between the right and left 1-screw tests within the same type of frameworks.
© 2011 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21492296     DOI: 10.1111/j.1532-849X.2011.00709.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  10 in total

1.  Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

Authors:  Walter Renne; Bethany Wolf; Raymond Kessler; Karen McPherson; Anthony S Mennito
Journal:  J Esthet Restor Dent       Date:  2015-07-14       Impact factor: 2.843

2.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

3.  Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report.

Authors:  Rubén Agustín-Panadero; David Peñarrocha-Oltra; Sonia Gomar-Vercher; Alberto Ferreiroa; Miguel Peñarrocha-Diago
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  The effect of framework fabrication technique on the fit accuracy of full arch screw retained implant supported prostheses.

Authors:  Fellwa AlRasheed; Khalid AlWazzan
Journal:  Saudi Dent J       Date:  2022-04-02

5.  Four-year outcomes of full-arch fixed dental prostheses using CAD/CAM frameworks: A retrospective review of 15 cases.

Authors:  Ilser Turkyilmaz; Niki-Haj Hariri
Journal:  J Clin Exp Dent       Date:  2018-10-01

6.  Effects of Different Surface Treatments on Bond Strength of Resin Cement to Machined Pure Titanium.

Authors:  Yang Cao; Yan-Yang Guo; Lei Chen; Jing Han; Hui Tong; Bao Zhang; Yu Zhang
Journal:  J Adhes Dent       Date:  2019       Impact factor: 2.359

7.  Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.

Authors:  Chui Ling Goo; Keson Beng Choon Tan
Journal:  Case Rep Dent       Date:  2017-03-15

8.  Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Authors:  Marzieh Alikhasi; Narges Ameri; Hakimeh Siadat; Ahmad Reza Shamshiri; Mohammadreza Nejati
Journal:  Front Dent       Date:  2019-06-29

9.  Fabrication of a customized impression metal jig for an implant-supported overdenture with a milled bar.

Authors:  Yeganeh Memari; Azadeh Tadayonfard; Amir Fayaz; Elaheh Beyabanaki
Journal:  Dent Res J (Isfahan)       Date:  2021-04-06

10.  A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: Application of a triple-scan protocol.

Authors:  Stefan Holst; Matthias Karl; Manfred Wichmann; Ragai E Matta
Journal:  J Dent Biomech       Date:  2012-07-20
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.