Literature DB >> 21489816

Biventricular cannulation is superior regarding hemodynamics and organ recovery in patients on biventricular assist device support.

Christian Schlensak1, David Schibilsky, Matthias Siepe, Kerstin Brehm, Rolf Klemm, Robert von Wattenwyl, Michael Berchthold-Herz, Christoph Benk, Friedhelm Beyersdorf.   

Abstract

BACKGROUND: Adequate pump flow is a prerequisite for recovery of end-organ failure and outcome in patients treated with a biventricular assist device (BiVAD). We hypothesized that hemodynamics and organ recovery would improve after biventricular, apical cannulation compared with right atrial cannulation.
METHODS: Between 2003 and 2009, we treated 31 patients (21 men, 10 women; mean age, of 43 ± 15 years) with a paracorporeal BiVAD (Thoratec BVAD, Pleasanton, CA). In 15 of 31 patients, the inflow cannula of the right VAD (RVAD) was positioned inside the right ventricle (RV) through the RV apex (biapical) instead of the right atrium (conventional). We analyzed pump flow, driving pressure, and vacuum of the Thoratec driving console and recovery of kidney (creatinine, blood urea nitrogen) and liver function (bilirubin).
RESULTS: Mean duration of BiVAD support was 84 ± 72 days. BiVAD weaning was successful in 4 of 31 patients (13%), 12 underwent cardiac transplantation (39%), and 15 (48%) died. We observed significantly higher pump flow of the LVAD and RVAD in patients after biapical cannulation compared with those with conventional cannulation (LVAD, 5.6 ± 0.4 vs 5.1 ± 0.3 liters/min, p = 0.002; and RVAD: 4.9 ± 0.3 vs 4.2 ± 0.3 liters/min, p < 0.001). This superior circulatory support correlated with faster recovery of kidney function.
CONCLUSION: Cardiac support with a BiVAD is hemodynamically more effective after biventricular apical cannulation compared with conventional right atrial cannulation. Consequently, higher pump flow results in better end-organ recovery using biapical cannulation.
Copyright © 2011 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21489816     DOI: 10.1016/j.healun.2011.02.013

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  2 in total

Review 1.  Cannulation techniques for extracorporeal life support.

Authors:  Evgeny Pavlushkov; Marius Berman; Kamen Valchanov
Journal:  Ann Transl Med       Date:  2017-02

Review 2.  Minimally-invasive LVAD Implantation: State of the Art.

Authors:  Jasmin S Hanke; Sebastian V Rojas; Murat Avsar; Axel Haverich; Jan D Schmitto
Journal:  Curr Cardiol Rev       Date:  2015
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.