Responses to dural puncture during institution of combined spinal-epidural analgesia: a comparison of 27 gauge pencil-point and 27 gauge cutting-edge needles.

A A van den Berg1, S Ghatge, G Armendariz, D Cornelius, S Wang.   

Abstract

Pencil-point spinal needles are popular for combined spinal-epidural analgesia because they cause less dural puncture headache than cutting-edge spinal needles. However many parturients move, grimace, vocalise or experience paraesthesia or dysaesthesia during dural puncture when performing 'needle through needle' combined spinal-epidural analgesia. We compared dural puncture responses induced by pencil-point and cutting-edge needles (both 27 gauge). With institutional approval, 115 parturients presenting for elective caesarean section or labour analgesia were audited. After lignocaine infiltration, a Tuohy-type needle was inserted to loss of resistance to saline at a mid-lumbar interspace, and either a 27 gauge cutting-edge or 27 gauge pencil-point needle was inserted 'needle through needle' through the dura. During dural penetration, the occurrence of patient movement, grimacing or vocalisation was noted by a blinded observer, as was the patient's response to the question "Did you feel that?" asked by the anaesthetist. The audit comprised two similar groups of patients (caesarean section, n=30; labour analgesia, n=85). In both groups, grimacing and movement during thecal penetration occurred more frequently with pencil-point needles (P < 0.05 and P < 0.025, respectively). Pooled data analysis revealed that pencil-point and cutting-edge needles induced grimacing and movement in 17 (22%) and 2 (5%), spontaneous vocalisation in 4 (5%) and 1 (3%) and was perceived by 13 (17%) and 3 (8%) parturients (P < 0.025, P=NS, P=NS), respectively. Overall, 34 and 6 objective and subjective patient responses (P < 0.005) occurred when inserting these needles, respectively. Dural puncture by a 27 gauge pencil-point needle inserted 'needle through needle' when instituting combined spinal-epidural analgesia induces more iatrogenic responses than a 27 gauge cutting-edge needle.

Entities:  

Mesh:

Year:  2011        PMID: 21485674     DOI: 10.1177/0310057X1103900215

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  4 in total

1.  A serum haemagglutinating property dependent upon polycarboxyl groups.

Authors:  M L Beck; B Freihaut; R Henry; S Pierce; W L Bayer
Journal:  Br J Haematol       Date:  1975-01       Impact factor: 6.998

Review 2.  Needle gauge and tip designs for preventing post-dural puncture headache (PDPH).

Authors:  Ingrid Arevalo-Rodriguez; Luis Muñoz; Natalia Godoy-Casasbuenas; Agustín Ciapponi; Jimmy J Arevalo; Sabine Boogaard; Marta Roqué I Figuls
Journal:  Cochrane Database Syst Rev       Date:  2017-04-07

3.  Is there a difference in postdural puncture headache after continuous spinal anesthesia with 28G microcatheters compared with punctures with 22G Quincke or Sprotte spinal needles?

Authors:  Eberhard Albert Lux; Astrid Althaus
Journal:  Local Reg Anesth       Date:  2014-11-10

4.  Factors associated with anesthetic satisfaction after cesarean delivery under neuraxial anesthesia.

Authors:  Mitsuru Ida; Junko Enomoto; Yumiko Yamamoto; Hiroki Onodera; Masahiko Kawaguchi
Journal:  JA Clin Rep       Date:  2018-09-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.