Literature DB >> 21483896

Peri-implant tissue response following connective tissue and bone grafting in conjunction with immediate single-tooth replacement in the esthetic zone: a case series.

Hirotaka Tsuda1, Kitichai Rungcharassaeng, Joseph Y K Kan, Phillip Roe, Jaime L Lozada, Grenith Zimmerman.   

Abstract

PURPOSE: This case series evaluated the peri-implant tissue response following extraction and immediate placement and restoration of an implant in conjunction with subepithelial connective tissue grafting (SCTG) and bone grafting in the esthetic zone. Implant success rates and the peri-implant tissue response were also reported. METHODS AND MATERIALS: Ten patients (four men, six women) with a mean age of 48 years (range, 35 to 70) underwent extraction and immediate tooth replacement with SCTG and were evaluated clinically and radiographically presurgically (T0), immediately after immediate tooth replacement and SCTG (T1), and at 3 months (T2), 6 months (T3), and 12 months (T4) after surgery. Data was analyzed using Friedman and Wilcoxon signed-ranks tests at the significance level of a = .05.
RESULTS: At 1 year, all implants remained osseointegrated, with an overall mean marginal bone change of +0.10 mm and a mean facial gingival level change of -0.05 mm. Modified Plaque Index scores showed that patients were able to maintain a good level of hygiene throughout the study. Papilla Index scores indicated that at T4, more than 50% papilla fill was observed in 80% of all sites.
CONCLUSIONS: The results of this case series suggest that, in addition to a favorable implant success rate and peri-implant tissue response, the facial gingival level around single immediately placed implants can also be maintained following connective tissue grafting when proper three-dimensional implant positioning is achieved and bone is grafted into the implant-socket gap.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21483896

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  Periodontics, Implantology, and Prosthodontics Integrated: The Zenith-Driven Rehabilitation.

Authors:  Fausto Frizzera; Mateus Tonetto; Guilherme Cabral; Jamil Awad Shibli; Elcio Marcantonio
Journal:  Case Rep Dent       Date:  2017-06-20

2.  Changes of the peri-implant soft tissue thickness after grafting with a collagen matrix.

Authors:  Gregory-George Zafiropoulos; Giorgio Deli; Oliver Hoffmann; Gordon John
Journal:  J Indian Soc Periodontol       Date:  2016 Jul-Aug

3.  Alveolar bone plate measurements of maxillary anterior teeth: A retrospective Cone Beam Computed Tomography study, AlMadianh, Saudi Arabia.

Authors:  Hamsah Sheerah; Badr Othman; Arwa Jaafar; Alla Alsharif
Journal:  Saudi Dent J       Date:  2019-04-13

4.  How Thick Is the Oral Mucosa around Implants after Augmentation with Different Materials: A Systematic Review of the Effectiveness of Substitute Matrices in Comparison to Connective Tissue Grafts.

Authors:  Martin Lissek; Martin Boeker; Arndt Happe
Journal:  Int J Mol Sci       Date:  2020-07-17       Impact factor: 5.923

5.  Immediate implant placement in conjunction with guided bone regeneration and/or connective tissue grafts: an experimental study in canines.

Authors:  Hyun-Chang Lim; Kyeong-Won Paeng; Myong Ji Kim; Ronald E Jung; Christoph Hf Hämmerle; Ui-Won Jung; Daniel S Thoma
Journal:  J Periodontal Implant Sci       Date:  2022-04       Impact factor: 2.086

Review 6.  Post extractive implant: evaluation of the critical aspects.

Authors:  L Tettamanti; C Andrisani; M Andreasi Bassi; R Vinci; J Silvestre-Rangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27

Review 7.  Soft Tissue Augmentation Techniques in Implants Placed and Provisionalized Immediately: A Systematic Review.

Authors:  Rosa Rojo; Juan Carlos Prados-Frutos; Ángel Manchón; Jesús Rodríguez-Molinero; Gilberto Sammartino; José Luis Calvo Guirado; Rafael Gómez-de Diego
Journal:  Biomed Res Int       Date:  2016-07-19       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.