Literature DB >> 21482140

Retrievability and device-related complications of the G2 filter: a retrospective study of 139 filter retrievals.

Xiaoli Zhu1, Matthew D B S Tam, John Bartholomew, James S Newman, Mark J Sands, Weiping Wang.   

Abstract

PURPOSE: To evaluate the retrievability and safety of the G2 filter.
MATERIALS AND METHODS: A retrospective study of all G2 filter retrievals at a single institution was conducted. Hospital records and imaging studies were reviewed for complications, and factors affecting retrieval were analyzed.
RESULTS: From 2005 to 2009, a total of 139 patients presented for retrieval of their G2 filter, and 131 pairs of pre- and post-placement cavagrams and 39 computed tomography scans were available for analysis. The following findings were recorded: limb penetration (n = 33), tilt greater than 15° (n = 22), local migration greater than 2 cm (n = 17), retained thrombus within the filter (n = 16), deformity (n = 10), inferior vena cava (IVC) occlusion (n = 3), fracture (n = 2), and pulmonary embolism breakthrough (n = 2). A total of 118 filters were removed, with a mean indwelling time of 131.8 days (range, 3-602 d). Indwell time (< 90, 90-180, or > 180 d) did not affect retrieval (P = .4). There were 21 filters (15.1%) left in situ as a result of severe tilt (n = 9), significant thrombus in the filter (n = 5), IVC occlusion (n = 3), filter incorporation into the caval wall (n = 3), or lack of central venous access (n = 1). There was a strong relationship between penetration and caudal migration (P < .0001). Severe tilt was associated with prolonged fluoroscopic times for retrieval (P = .003).
CONCLUSIONS: The majority of G2 filters can be removed without difficulty. The most common factor affecting retrieval was severe tilting. The indwelling time had no impact on retrieval. G2 filter-related complications were frequent but most, including fractures, were clinically insignificant.
Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21482140     DOI: 10.1016/j.jvir.2011.01.430

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  8 in total

1.  Factors associated with reduced radiation exposure, cost, and technical difficulty of inferior vena cava filter placement and retrieval.

Authors:  Matthew Neill; Hearns W Charles; Daniel Pflager; Amy R Deipolyi
Journal:  Proc (Bayl Univ Med Cent)       Date:  2017-01

Review 2.  Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type.

Authors:  Steven E Deso; Ibrahim A Idakoji; William T Kuo
Journal:  Semin Intervent Radiol       Date:  2016-06       Impact factor: 1.513

3.  Persistent Abdominal Pain as Rare Complication of Duodenal Perforation From an Inferior Vena Cava Filter.

Authors:  Walid Khan; Wei Zhang; Virginia Clark
Journal:  Cureus       Date:  2021-02-06

4.  IVC filter retrieval in adolescents: experience in a tertiary pediatric center.

Authors:  Anthony K Guzman; Mahmoud Zahra; Scott O Trerotola; Leslie J Raffini; Maxim Itkin; Marc S Keller; Anne Marie Cahill
Journal:  Pediatr Radiol       Date:  2016-01-21

5.  An analysis of factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval.

Authors:  Mark Kleedehn; Kelli Moore; Katherine Longo; Kaitlin Woo; Paul Laeseke
Journal:  Eur Radiol       Date:  2018-10-09       Impact factor: 5.315

Review 6.  Over-the-Wire Inferior Vena Cava Filter Placement: How We Do It.

Authors:  Xin Li; Jennifer Montgomery; Levester Kirksey; Sameer Gadani; Giuseppe D'Amico; Sasan Partovi
Journal:  Semin Intervent Radiol       Date:  2021-06-03       Impact factor: 1.780

7.  Over-the-wire deployment techniques of option elite inferior vena cava filter: 3D printing vena cava phantom study.

Authors:  Byung Geon Park; Anna Seo; Sang Yub Lee; Jung Guen Cha; Jihoon Hong; Hoseok Lee; Jun Heo; Young Woo Do
Journal:  Eur J Radiol Open       Date:  2020-03-21

8.  Is external compression on the IVC a risk factor for IVC filter abutment? A single center experience of 141 infrarenal celect filter insertions.

Authors:  Sang Yub Lee; Jongmin Lee
Journal:  Eur J Radiol Open       Date:  2018-05-04
  8 in total