Literature DB >> 21481882

Coupled reversed-phase and ion chromatographic system for the simultaneous identification of inorganic and organic explosives.

Eadaoin Tyrrell1, Greg W Dicinoski, Emily F Hilder, Robert A Shellie, Michael C Breadmore, Christopher A Pohl, Paul R Haddad.   

Abstract

There are many methods available to detect and positively identify either organic or inorganic explosives separately, however no one method has been developed which can detect both types of explosive species simultaneously from a single sample. In this work, a unique coupled-chromatographic system is reported for the simultaneous determination of both organic and inorganic explosive species and is used for pre-blast analysis/identification purposes. This novel approach is based on the combination of reversed-phase high performance liquid chromatography and ion chromatography which allows trace levels of organic and inorganic explosives to be determined simultaneously from a single sample. Using this procedure, a 20 min reversed-phase separation of organic explosives is coupled to a 16 min ion-exchange separation of anions present in inorganic explosives, providing a complete pre-blast analysis/identification system for the separation and detection of a complex mixture containing organic and/or inorganic explosive species. The total analysis time, including sufficient column re-equilibration between runs, was <25 min using the coupled system. By this method, the minimum resolution for the organic separation was 1.16 between nitroglycerin and tetryl and the detection limits ranged from 0.31 mg L(-1) for cyclotetramethylene tetranitramine (HMX) and 1.54 mg L(-1) for pentaerythrite tetranitrate (PETN), while the minimum resolution for the inorganic separation was 0.99 between azide and nitrate, and the detection limits ranged from 7.70 μg L(-1) for fluoride and 159.50 μg L(-1) for benzoate. Crown
Copyright © 2011. Published by Elsevier B.V. All rights reserved.

Mesh:

Substances:

Year:  2011        PMID: 21481882     DOI: 10.1016/j.chroma.2011.03.046

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Overcoming selectivity and sensitivity issues of direct inject electrospray mass spectrometry via DAPNe-NSI-MS.

Authors:  Kristina Clemons; Chinyere Nnaji; Guido F Verbeck
Journal:  J Am Soc Mass Spectrom       Date:  2014-03-11       Impact factor: 3.109

2.  Ultrasensitive, Real-time and Discriminative Detection of Improvised Explosives by Chemiresistive Thin-film Sensory Array of Mn(2+) Tailored Hierarchical ZnS.

Authors:  Chaoyu Zhou; Zhaofeng Wu; Yanan Guo; Yushu Li; Hongyu Cao; Xuefang Zheng; Xincun Dou
Journal:  Sci Rep       Date:  2016-05-10       Impact factor: 4.379

3.  The Development of Digital Image Colorimetric Quantitative Analysis of Multi-Explosives Using Polymer Gel Sensors.

Authors:  Yudtapum Thipwimonmas; Adul Thiangchanya; Apichai Phonchai; Sittipoom Thainchaiwattana; Wachirawit Jomsati; Sunisa Jomsati; Kunanunt Tayayuth; Warakorn Limbut
Journal:  Sensors (Basel)       Date:  2021-12-01       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.