Trajectory of the center of rotation in non-articulated energy storage and return prosthetic feet.

Andrew Sawers1, Michael E Hahn.   

Abstract

Non-articulated energy storage and return prosthetic feet lack any true articulation or obvious point of rotation. This makes it difficult to select a joint center about which to estimate their kinetics. Despite this absence of any clear point of rotation, methods for estimating the kinetic performance of this class of prosthetic feet typically assume that they possess a fixed center of rotation and that its location is well approximated by the position of the contralateral lateral malleolus. To evaluate the validity of this assumption we used a finite helical axis approach to determine the position of the center of rotation in the sagittal plane for a series of non-articulated energy storage and return prosthetic feet. We found that over the course of stance phase, the sagittal finite helical axis position diverged markedly from the typically assumed fixed axis location. These results suggest that researchers may need to review center of rotation assumptions when assessing prosthetic foot kinetics, while clinicians may need to reconsider the criteria by which they prescribe these prosthetic feet. Published by Elsevier Ltd.

Mesh:

Substances:

Year:  2011        PMID: 21481878     DOI: 10.1016/j.jbiomech.2011.03.028

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

Review 1.  Ankle and foot power in gait analysis: Implications for science, technology and clinical assessment.

Authors:  Karl E Zelik; Eric C Honert
Journal:  J Biomech       Date:  2018-04-18       Impact factor: 2.712

2.  Sensitivity, reliability and accuracy of the instant center of rotation calculation in the cervical spine during in vivo dynamic flexion-extension.

Authors:  Emma Baillargeon; William J Anderst
Journal:  J Biomech       Date:  2013-01-12       Impact factor: 2.712

3.  Adaptation and prosthesis effects on stride-to-stride fluctuations in amputee gait.

Authors:  Shane R Wurdeman; Sara A Myers; Adam L Jacobsen; Nicholas Stergiou
Journal:  PLoS One       Date:  2014-06-23       Impact factor: 3.240

4.  Increasing prosthetic foot energy return affects whole-body mechanics during walking on level ground and slopes.

Authors:  W Lee Childers; Kota Z Takahashi
Journal:  Sci Rep       Date:  2018-03-29       Impact factor: 4.379

5.  Biomechanical evaluation over level ground walking of user-specific prosthetic feet designed using the lower leg trajectory error framework.

Authors:  Victor Prost; W Brett Johnson; Jenny A Kent; Matthew J Major; Amos G Winter
Journal:  Sci Rep       Date:  2022-03-29       Impact factor: 4.379