Literature DB >> 21478789

Femoral artery catheterization in neonates and infants.

Alison Artico Dumond1, Eduardo da Cruz, Melvin C Almodovar, Robert H Friesen.   

Abstract

OBJECTIVE: To determine the incidence of perfusion-related complications associated with indwelling femoral artery monitoring catheters in neonates and infants following introduction of a 2.5-F diameter, 5-cm length, polyethylene catheter (Cook Medical, Bloomington, IN) to our unit.
DESIGN: Prospective observational cohort study.
SETTING: Pediatric cardiac intensive care unit in a university-affiliated children's hospital. PATIENTS: All patients <2 yrs old with an indwelling femoral artery catheter during a 3-yr period.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Two hundred eighty-two patients (including 98 neonates), median (range) age 10 wks (0.1-84), weight 4.1 kg (2.0-11.1) were enrolled; outcomes in 249 were evaluable. Pulse strength in dorsalis pedis arteries and pulse discrepancies between feet were assessed hourly by the cardiac intensive care unit nurse and recorded on a flow sheet. Nonpalpable pulses were assessed as "absent" or "present" with ultrasonic Doppler. Following removal of the catheter, assessments of pulse strength continued until resolution of any discrepancies. Median (range) duration of catheterization was 4 days (1-23). Catheters of 2.5-F diameter were used in 227 patients and larger catheters in 55 patients. The incidence of pulse strength discrepancies between feet was 20%, loss of pulse was 3.4% (6.7% in neonates, 1.4% in older infants) when extracorporeal membrane oxygenation patients were excluded, and resolution of pulse discrepancy or loss was 100%. Duration of catheterization and use of a catheter larger than 2.5 Fr were significant predictors of loss of pulse.
CONCLUSIONS: Loss of pedal pulse distal to small-bore monitoring femoral artery catheters in neonates and infants is directly related to the duration of catheterization and is less frequent when 2.5-F, 5-cm polyethylene catheters are used instead of larger catheters.

Entities:  

Mesh:

Year:  2012        PMID: 21478789     DOI: 10.1097/PCC.0b013e3182192c7b

Source DB:  PubMed          Journal:  Pediatr Crit Care Med        ISSN: 1529-7535            Impact factor:   3.624


  5 in total

1.  Limb length shortening associated with femoral arterial lines in the neonatal period.

Authors:  Anne R Synnes; Christopher Reilly; Ashley Robinson
Journal:  Paediatr Child Health       Date:  2013-04       Impact factor: 2.253

2.  Cardiac Catheterisation Interventions in Neonates and Infants Less Than Three Months.

Authors:  Ali A Alakhfash; Ali Jelly; Abdulrahman Almesned; Abdullah Alqwaiee; Mansour Almutairi; Sherif Salah; Mahmoud Hasan; Mustafa Almuhaya; Abdulhamid Alnajjar; Mohammed Mofeed; Bana Nasser
Journal:  J Saudi Heart Assoc       Date:  2020-05-12

3.  Transient flow response after femoral artery catheterization for diagnostic neuroangiography in infants and children: Doppler US assessment of the ipsilateral femoral artery.

Authors:  Seong Ho Kim; Young Hun Choi; Jung-Eun Cheon; Su-Mi Shin; Hyun-Hae Cho; So Mi Lee; Sun Kyoung You; Woo Sun Kim; In-One Kim
Journal:  Pediatr Radiol       Date:  2014-07-06

4.  Treatment of a severe distal thoracic and abdominal coarctation with cutting balloon and stent implantation in an infant: From fetal diagnosis to adolescence.

Authors:  Karlien Carbonez; Joëlle Kefer; Thierry Sluysmans; Stephane Moniotte
Journal:  Health Sci Rep       Date:  2022-04-25

5.  Intra-Arterial Chemotherapy as Primary Therapy for Retinoblastoma in Infants Less than 3 Months of Age: A Series of 10 Case-Studies.

Authors:  Miaojuan Chen; Junyang Zhao; Jiejun Xia; Zhenyin Liu; Hua Jiang; Gang Shen; Haibo Li; Yizhou Jiang; Jing Zhang
Journal:  PLoS One       Date:  2016-08-09       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.