| Literature DB >> 21478621 |
Lihong He1, Li Yang, Aizhen Xiong, Shujuan Zhao, Zhengtao Wang, Zhibi Hu.
Abstract
An ultra-performance liquid chromatography/mass spectrometry method to simultaneously quantify vindoline, catharanthine, serpentine and ajmalicine in Catharanthus roseus cell line C20hi is reported. Samples were extracted with 1% acetic acid, basified to pH 10 with ammonia, then extracted with ethyl acetate, dried, reconstituted with methanol-1% acetic acid water solution (1:1, v/v) and analyzed using an acetonitrile-0.1% formic acid gradient as the mobile phase. Detection was carried out by electrospray ionization mass spectrometry in the positive-ion mode with selective ion monitoring. The analysis of one sample was achieved in 6 min. The limits of detection were 0.46 - 0.70 ng/ml in cell samples, and 0.10 - 0.16 ng/ml in medium samples. The linearity of detection was over the wide range of 1.00 - 6250.0 ng/ml. Intra- and inter-day accuracies (recovery 88.0 - 111.8%) and precision (RSD 1.25 - 7.81%) showed the performance of the assay. This method provides a more sensitive and high-throughput technique to quantify the four alkaloids in large amount of samples, and will be helpful in high-production cultivar screening.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21478621 DOI: 10.2116/analsci.27.433
Source DB: PubMed Journal: Anal Sci ISSN: 0910-6340 Impact factor: 2.081